7.
Electrical Installations
80
Bat. 1: 095 Ah AGM
Motor:
080 Ah
GEL
12:30
23,5 °C
09.01.15
18,0 °C
Setting the battery type
The type and capacity of the batteries have been set by the ma-
nufacturer. These settings must be changed when the type of
battery is changed.
Use the arrow keys or the control knob to select the desired
value. Increase or decrease it by means of the +/- functions. If
the control knob is used to change a value, the new value must
be confirmed by pressing on the control knob.
Exit this menu by using the “Back” function; otherwise, after
one minute, it will automatically switch back to the main menu
on the control panel.
If the set values do not match those of the battery that was
installed, incorrect values will be displayed in the battery
management. Setting the type of battery has an effect on
the charging behaviour; therefore, this must be set correctly.
Bat. 1:
SOH: 42 %
U : 14,2 V
Bat. Mot.:
SOH: 92 %
U : 14,2 V
12:30
23,5 °C
09.01.15
18,0 °C
Warning message: age of battery
(SoH = State of Health)
This warning appears when the ori-
ginal capacity of a battery drops to
a value of less than 50%.
To enable this message to appear, the battery sensors must be ca-
librated.
The message can be acknowledged; the battery in question should
be replaced.
Error messages
12:30
23,5 °C
09.01.15
18,0 °C
Warning message: undervoltage
This warning appears when a vol-
tage of 10.8V or less is measured
for a battery for a duration of at
least 3 minutes.
The icon for the battery, habitation or starter battery in question
appears in the menu.
The message can be acknowledged; the battery should be
charged immediately.