10. Built-in devices
132
1.
Starting and changing the different heating levels step by step
(Off, 1 kW, 2 kW or 3 kW)
with "+" or "-". The value set will be
displayed on the screen. When activated, the plus icon is shown
in green.
2.
To switch off the electric heating operation, keep pressing the "-"
key until you reach
Off.
Heating with gas
To activate heating with gas:
If electricity and gas are selected together, you can set whether gas or
electricity is to take priority
(see Tools menu).
1.
Start gas operation by pressing on the liquid gas flame. The icon
for liquid gas is activated and turns green.
2.
To switch off gas operation, press the liquid gas flame. The icon is
now blue.
Hot-water floor heating system for ALDE hot-water heating *
If the caravan is fitted with a hot-water floor heating system, the
floor is heated by a system of pipes through which hot water flows.
In combination with heat transfer plates the heat is dispersed throug-
hout the entire floor of the vehicle.
Switching the hot-water floor heating system on and off
To operate the hot-water floor heating system, the hot-water heating
system must be switched on. This can be controlled via the control
panel or via HobbyConnect*
(see also descriptions in Chapters 7.3
and 7.3.1)
as well as via the manufacturer’s own control panel for the
ALDE 3020 HE.
The hot-water floor heating system is controlled via regulating valves
located in the front and rear areas of the caravan (depending on the
layout plan). These valves are used to set the flow control for the
hot-water floor heating system. However, how intense the heat is
depends on the heat setting for the hot-water heating.
Maximum opening is reached by setting the valves in the direction of
the pipes. If the valves are turned by 90° to the right, they are then
closed.
To prevent heat build-up in one spot, do not place objects
for a long period of time on the hot-water floor heating
system.
Never drill holes in the floor or insert screws.
To prevent damage to the regulating valves, do not use
the space around the valves for storage.
Valves in open position
Valves in closed position