68
7. Installation of electrical
devices
Batterie-
management
U : 12,3 V
I : 5,3 A
: 6,5 h
T : 0,0 °C
R : 0
Charger
GEL
060 Ah
12:25
27,4°C
06.06.16
26,4°C
12:25
27,4°C
06.06.16
26,4°C
Error messages
12:25
27,4 °C
06.06.16
26,4 °C
Warning message: Low voltage
This warning appears when a voltage of 10.8V or less is measured
for a battery for a duration of at least 3 minutes. The icon for the
battery in question appears in the menu.
The message can be acknowledged; the battery should be charged
immediately.
Bat. 1:
SOH: 42 %
U : 14,2 V
12:25
27,4 °C
06.06.16
26,4 °C
Warning message: age of battery
(SoH = State of Health)
This warning appears when the original capacity of a battery drops to a
value of less than 50%.
To enable this message to appear, the battery sensor must be ca
-
librated.
The message can be acknowledged; the battery should be replaced.
Exit this menu by using the “Back” function; otherwise, after one minute,
it will automatically switch back to the main menu on the control panel.
Setting the battery type
The type and capacity of the batteries have been set by the manuf
-
acturer. These settings must be changed when the type of battery
is changed.
Use the arrow keys or the control knob to select the desired value.
Increase or decrease it by means of the +/- functions. If the control
knob is used to change a value, the new value must be confirmed
by pressing on the control knob.
If the set values do not match those of the battery that
was installed, incorrect values will be displayed in the
battery management. Setting the type of battery has an
effect on the charging behaviour; therefore, this must be
set correctly.
If the icons for the “Charger” appear, the caravan is
connected to a 230V mains connection and the charge
controller was recognised: the battery will be charged.
If the caravan is connected to a 230V mains connection
and the icons for the Charger do not appear, is loaded
according to characteristic.