6-2
●
Wiring precautions
+++
+++
Signal ground
Nozzle Ink column Charge electrode
Primary power cable
Print head unit
Stand (option)
Spaced by insulator
IJ printer body frame
Welding work cautions
E
(3) Precautions related to welding current of welder
Signal (weak electric) ground and frame ground are connected because the ink drops of the IJ printer
are electrically charged.
The ink drops are electrically charged by impressing a volt-
age between the charging electrode and ink column as
shown at the left.
Therefore, the ink always becomes signal ground.
In addition, since the ink is always connected to frame
ground by the clamp, etc. of the circulation path, separating
signal ground and frame ground is difficult.
Charge theory
Therefore, when a large current (for example, the welding current of a welder) flows from the
outside through frame ground, the current is also diverted to signal ground and the PC boards may
be damaged. For this reason, when performing welding work near the IJ printer, proceed as follows:
Method
Be sure to insulate the printhead and IJ printer frame to keep the welding current from flowing to
the control section of the printer, and to make a separate ground connection for the printer.
If this method is used, welding work becomes possible even while the IJ printer is operating.
●
Fire is strictly forbidden around the IJ printer
The ink and makeup are both flammable. Welding sparks may cause ignition or a fire.
Take measures so that sparks do not enter the surrounding area whether or not the IJ
printer is operating, and ventilate sufficiently.
Just in case, ensure safety by installing a powder type fire extinguisher nearby.
WARNING