YUTAKI S80
Version for indoor unit alone
Model
Power supply
Applicable voltage
Operation mode
MC
(A)
CB
(A)
ELB
(nº of poles/A/mA)
U max. (V)
U min. (V)
RWH-4.0VNFE
1~ 230V 50Hz
253
207
Without DHW tank heater
24
32
2/40/30
With DHW tank heater
38
40
RWH-5.0VNFE
Without DHW tank heater
28
32
With DHW tank heater
42
50
2/63/30
RWH-6.0VNFE
Without DHW tank heater
31
32
2/40/30
With DHW tank heater
45
50
2/63/30
RWH-4.0NFE
3N~ 400V 50Hz
440
360
Without DHW tank heater
10
15
4/40/30
With DHW tank heater
24
25
RWH-5.0NFE
Without DHW tank heater
10
15
With DHW tank heater
24
25
RWH-6.0NFE
Without DHW tank heater
10
15
With DHW tank heater
24
25
Version for combination with DHW tank
Model
Power supply
Applicable voltage
Operation mode
MC
(A)
CB
(A)
ELB
(nº of poles/A/mA)
U max. (V)
U min. (V)
RWH-4.0VNFWE
1~ 230V 50Hz
253
207
Without DHW tank heater
24
32
2/40/30
With DHW tank heater
36
40
RWH-5.0VNFWE
Without DHW tank heater
28
32
With DHW tank heater
40
50
2/63/30
RWH-6.0VNFWE
Without DHW tank heater
31
32
2/40/30
With DHW tank heater
43
50
2/63/30
RWH-4.0NFWE
3N~ 400V 50Hz
440
360
Without DHW tank heater
10
15
4/40/30
With DHW tank heater
22
25
RWH-5.0NFWE
Without DHW tank heater
10
15
With DHW tank heater
22
25
RWH-6.0NFWE
Without DHW tank heater
10
15
With DHW tank heater
22
25
?
N O T E
The data corresponding to DHW tank heater is calculated in combination with the YUTAKI S80 domestic hot water tank accessory
“DHWS(200/260) S-2.7H2E(-W)”.
ELECTRICAL AND CONTROL SETTINGS
PMML0575 rev.2 - 03/2022
82