4.5 MONOBLOC SYSTEM
YUTAKI M (R32)
RASM-(2/3)VRE
Model
Power supply
Applicable voltage
Operation mode
Cooling
operation
Heating
operation
MC
(A)
Max.
IPT
(kW)
U max.
(V)
U min.
(V)
RNC
(A)
IPT
(KW)
RNC
(A)
IPT
(KW)
RASM-2VRE
1~ 230V 50Hz
253
207
Without DHW tank heater
4.8
1.00
5.5
1.14
10.6
2.32
With DHW tank heater
4.8
1.00
18.8
3.89
23.1
5.07
RASM-3VRE
Without DHW tank heater
9.4
1.94
8.9
1.84
16.0
3.54
With DHW tank heater
9.4
1.94
22.2
4.59
28.5
6.29
?
N O T E
The data corresponding to DHW tank heater is calculated in combination with the domestic hot water tank accessory “DHWT-(200/300)S-3.0H2E”.
YUTAKI M (R410A)
RASM-(4-6)(V)NE
Model
Power supply
Applicable voltage
Operation mode
Cooling
operation
Heating
operation
MC
(A)
Max.
IPT
(kW)
U max.
(V)
U min.
(V)
RNC
(A)
IPT
(KW)
RNC
(A)
IPT
(KW)
RASM-4VNE
1~ 230V 50Hz
253
207
Without DHW tank heater
9.7
2.20
9.6
2.18
30.8
7.01
With DHW tank heater
21.7
4.95
9.6
2.18
43.3
9.88
RASM-5VNE
Without DHW tank heater
13.1
2.97
13.0
2.95
30.8
7.01
With DHW tank heater
25.1
5.72
12.9
2.95
43.3
9.88
RASM-6VNE
Without DHW tank heater
15.4
3.50
16.4
3.72
30.8
7.01
With DHW tank heater
27.4
6.25
16.3
3.72
43.3
9.88
RASM-4NE
3N~ 400V
50Hz
440
360
Without DHW tank heater
3.6
2.20
3.6
2.18
14.3
8.77
With DHW tank heater
11.4
4.95
5.0
2.18
26.8
11.65
RASM-5NE
Without DHW tank heater
4.8
2.97
4.8
2.95
14.3
8.77
With DHW tank heater
13.2
5.72
6.8
2.95
26.8
11.65
RASM-6NE
Without DHW tank heater
4.8
2.97
4.8
2.95
16.3
10.02
With DHW tank heater
12.8
5.72
6.6
2.95
28.8
12.90
?
N O T E
The data corresponding to DHW tank heater is calculated in combination with the domestic hot water tank accessory “DHWT-(200/300)S-3.0H2E”.
ELECTRICAL DATA
PMML0575 rev.2 - 03/2022
30