List of available outputs:
•
Disabled
•
SWP 3WV:
(Fixed in output 1 if swimming pool is enabled): Signal control of the 3-way valve of the swimming pool.
•
Water pump 3:
(Fixed in output 2 if hydraulic separator or buffer tank is installed): Signal control of the water pump for hydraulic
separator or buffer tank.
•
Boiler:
(Fixed in input 3 if boiler is enabled): Signal control of the boiler.
•
Solar Pump:
(Fixed in input 4 if solar pump is enabled): Signal control of the solar pump.
•
Alarm:
(By default in output 5):Signal is active if there is an alarm.
•
Operation:
(By default in output 6): Signal active in case Thermo ON in any condition.
•
Cooling:
(By default in output 7): Signal active when space cooling is operating.
•
Dem-ON C1:
(By default in output 8): Signal active when there is Demand in circuit 1.
•
Heating:
Signal active when space heating is operating.
•
DHW:
Signal active when DHW is operating.
•
Solar overheat:
Signal is active when solar overheat (only when solar combination status is total control)
•
Defrost:
Signal active when outdoor unit is defrosting.
•
DHW Re-circulation:
Signal active depending on option selected at chapter Circuit pump.
•
Heater relay 1:
Signal control of the Space heating heater 1 (Only for YUTAKI S80 or YUTAKI M units)
•
Heater relay 2:
Signal control of the Space heating heater 2 (Only for YUTAKI S80 or YUTAKI M units)
List of available sensors:
•
Disabled
•
Two3:
(Fixed in sensor 1 if boiler is installed): Use this sensor to monitor water temperature when boiler is used.
•
Swimming Pool:
(Fixed in sensor 2 if swimming pool is installed): Use this sensor when swimming pool is used in order to
monitor swimming pool temperature.
•
Solar panel sensor:
Use this sensor when Total control is configured to monitor Solar Panel temperature.
•
C1 + C2 Ambient:
Use this sensor when auxiliary ambient temperature sensor is used for C1 and C2.
•
C1 Ambient:
Use this sensor when auxiliary ambient temperature sensor is used for C1.
•
C2 Ambient:
Use this sensor when auxiliary ambient temperature sensor is used for C2.
•
Outdoor sensor (NTC):
(By default sensor 3)
To connect to the controller an auxiliary outside temperature sensor in case the
heat pump is located in a position not suitable for this measurement.
10.6.3 Controller settings
Under the controller settings menu it is possible to adjust the several parameters:
Controller options:
•
Favourite action (Eco/Comfort, DHW Boost, Timer)
Room names:
•
Create or edit a name for circuit 1 or circuit 2
Date and time:
• Adjust date and time
•
European summer time
Selection of the unit controller language.
Screen settings:
• Screen brightness
•
Backlight time
• Contrast
•
ON led bright
YUTAKI CASCADE CONTROLLER ATW-YCC-(01-02)
PMML0575 rev.2 - 03/2022
263