8.6.2.1
Examples of possible configurations
?
N O T E
•
Other installation configurations are possible. These are examples only for illustration purposes.
•
It is recommended to set firstly the Master device so as the ease the configuration of the slave devices.
Example 1
1
Master unit controller as unit configuration.
2
Slave Unit controller as a room thermostat for Zone 1, as accessory
3
Slave Unit controller as a room thermostat for Zone 2, as accessory
OK
OK
OK
Outdoor unit
Indoor unit
1
2
3
Living room Zone 1
Bedroom Zone 2
Order
FIRST
SECOND
THIRD
Type
Master
Slave
Slave
Unit
Circuit 1
Circuit 2
Questions
Answers
Is this device attached to the unit?
YES
-
-
Is this device used as a Room Thermostat of a zone?
NO
YES, IN ZONE 1
YES, IN ZONE 2
How many circuits do you have?
2
-
-
Which are the emitters of circuit 1?
Underfloor heating
-
-
Which are the emitters of circuit 2?
Underfloor heating
-
-
Do you have domestic hot water tank?
NO
-
-
Do you have swimming pool?
NO
-
-
Do you have boiler?
NO
-
-
Do you have electric backup heater?
NO
-
-
Which Thermostat do you have for Circuit 1?
Wired
-
-
Which Thermostat do you have for Circuit 2?
Wired
-
-
COMPLETED
COMPLETED
COMPLETED
UNIT CONTROLLER (PC-ARFH1E)
PMML0575 rev.2 - 03/2022