Indoor unit in combination with DHW tank
Model
Power supply
Operation mode
Z
max
(Ω)
RWH-4.0VNFWE
1~ 230V 50Hz
Without DHW tank heater
0.31
With DHW tank heater
0.21
RWH-5.0VNFWE
Without DHW tank heater
0.27
With DHW tank heater
0.19
RWH-6.0VNFWE
Without DHW tank heater
0.24
With DHW tank heater
0.17
RWH-4.0NFWE
3N~ 400V 50Hz
Without DHW tank heater
-
With DHW tank heater
0.41
RWH-5.0NFWE
Without DHW tank heater
-
With DHW tank heater
0.41
RWH-6.0NFWE
Without DHW tank heater
-
With DHW tank heater
0.41
?
N O T E
The data corresponding to DHW tank heater is calculated in combination with the YUTAKI S80 domestic hot water tank accessory
“DHWS(200/260) S-2.7H2E(-W)”.
Monobloc system - R410A YUTAKI M
Model
Power supply
Operation mode
Z
max
(Ω)
RASM-4VNE
1~ 230V 50Hz
Without DHW tank heater
0.24
With DHW tank heater
0.17
RASM-5VNE
Without DHW tank heater
0.24
With DHW tank heater
0.17
RASM-6VNE
Without DHW tank heater
0.24
With DHW tank heater
0.17
RASM-4NE
3N~ 400V 50Hz
Without DHW tank heater
-
With DHW tank heater
0.31
RASM-5NE
Without DHW tank heater
-
With DHW tank heater
0.31
RASM-6NE
Without DHW tank heater
-
With DHW tank heater
0.30
?
N O T E
The data corresponding to DHW tank heater is calculated in combination with the domestic hot water tank accessory “DHWT-(200/300)S-3.0H2E”.
Monobloc system - R32 YUTAKI M
Model
Power supply
Operation mode
Z
max
(Ω)
RASM-2VRE
1~ 230V 50Hz
-
-
With DHW tank heater
0.30
RASM-3VRE
-
0.43
With DHW tank heater
0.24
?
N O T E
The data corresponding to DHW tank heater is calculated in combination with the domestic hot water tank accessory “DHWT-(200/300)S-3.0H2E”.
ELECTRICAL AND CONTROL SETTINGS
PMML0575 rev.2 - 03/2022
74