8.8.2.9
Optional functions configuration
This menu allows to configure the optional functions for system, space heating or space cooling, DHW and Emergency operation.
DHW:
Configure the optional functions for the DHW. See detailed
information below.
Emergency operation:
Enable or disable emergency operation for space heating or
DHW. See detailed information below.
System:
Configure the optional functions for the system. See detailed
information below.
Space functions:
Configure the optional functions for the space heating or space
cooling. See detailed information below.
System optional functions
Hydraulic separator status:
Enable if there is a Hydraulic separator or a
buffer tank installed. Check that WP3 is set
in output 2 (see section
Outputs and Sensors configuration”
)
Energy configuration:
Setup of power consumption readings. See
detailed information below.
Smart function:
To block or limit the heat pump or increase
demand due to electricity availability. See
detailed information below.
Energy configuration
Status:
Enable or disable energy configuration options
Capacity configuration:
Due to usage of water temperature inlet and outlet
+ water flow level, an estimation of capacity can
be checked through the Operation information -
Energy data menu.
Power meter 1 or 2:
•
The power meter does a real measuring of
the power consumption.
•
If the power meter is enabled, it is possible
to see the information collected through the
Operation information - Energy data menu.
•
If “power meter” is disabled the YUTAKI
software does an estimate consumption of
the system.
•
In case of using power meter 1 or 2 input
must be configured at the Inputs menu
(see section
UNIT CONTROLLER (PC-ARFH1E)
PMML0575 rev.2 - 03/2022