12-7
Display
(Function mode 1)
(Function mode 2)
Setting, change
sequence
Function
Function
Initialization display
Initialization
contents
Setting contents
No.
name
contents
9
F-08
Accelera-
Fsp F
0000.0 Hz
0 Hz
0 to 400.0
• The frequency at which the
Accelera-
tion stop
acceleration operation is
tion halt
frequency
stopped temporarily is set.
setting
Accelera-
Fsp TIME
00.0 s
0 s
0 to 60.0
• The time that the acceleration
tion stop
is stopped temporarily at a
time setting
certain frequency during
acceleration is set.
10
F-09
Pattern
PARAM
REM
REM
REM/
• The parameter setting com-
command-
OP1/OP2
manding source is selected.
ing method
(Option
REM (each operator),
selection
connected)
OP1 (option 1), OP2 (option
2)
11
F-10
Running
mode
Running
RUN MODE
NOR
NOR
NOR/OEN/
NOR:
Normal running
mode
GOD
OEN:
Energy conservation
selection
running
GOD:
Fuzzy most suitable
acceleration and
deceleration running
Restarting
RUN FRS
ZST
ZST
fST/ZST
fST:
Restart after frequency
after FRS
maching
signal
ZST:
0 Hz start
selection
12
F-11
Multistage
SPD 1
0000.00 Hz
0 Hz
0 to 120.0 (400)
• The input terminal CF1 is set
Multistage speed
and used.
speed
1 speed
setting
Multistage
SPD 2
0000.00 Hz
0 Hz
0 to 120.0 (400)
• The input terminal CF2 is set
speed
and used.
2-speed
setting
Multistage
SPD 3
0000.00 Hz
0 Hz
0 to 120.0 (400)
• The input terminals CF1 and
speed
CF2 are set and used.
3-speed
setting
Multistage
SPD 4
0000.00 Hz
0 Hz
0 to 120.0 (400)
• The input terminals CF1 and
speed
CF3 are set and used.
4-speed
setting
Multistage
SPD 5
0000.00 Hz
0 Hz
0 to 120.0 (400)
• The input terminals CF2 and
speed
CF3 are set and used.
5-speed
setting
Multistage
SPD 6
0000.00 Hz
0 Hz
0 to 120.0 (400)
• The input terminals CF1, CF2,
speed
and CF3 are set and used.
6-speed
setting
Multistage
SPD 7
0000.00 Hz
0 Hz
0 to 120.0 (400)
• The input terminal CF3 is set
speed
and used.
7-speed
setting