86
4.2
System Clock Generator
Clock pulses can be supplied to the system clock divider either by connecting a crystal or ceramic
oscillator, or by providing external clock input.
1. Connecting a crystal oscillator
Figure 4-2 shows a typical method of connecting a crystal oscillator.
1
2
C
1
C
2
OSC
OSC
R = 1 M
Ω
±
20%
f
R
f
Oscillation
Recommended value
frequency
Manufacturer
for C
1
and C
2
4.0 MHz
Nihon Denpa Kogyo
12 pF
±
20%
Figure 4-2 Typical Connection to Crystal Oscillator
Figure 4-3 shows the equivalent circuit of a crystal oscillator. An oscillator having the
characteristics given in table 4-1 should be used.
C
S
C
0
R
S
OSC
1
OSC
2
L
S
Figure 4-3 Equivalent Circuit of Crystal Oscillator
Table 4-1
Crystal Oscillator Parameters
Frequency
4.193 MHz
R
S
(max)
100
Ω
C
0
(max)
16 pF