![Hitachi H8/3935 Hardware Manual Download Page 401](http://html.mh-extra.com/html/hitachi/h8-3935/h8-3935_hardware-manual_140486401.webp)
389
12.6.2
Start-up Timing
The following diagram and table describe the timing specifications of the FLEX decoder when
power is applied.
VDD
t
START
t
RESET
t
RHRL
Oscillator
RESET
READY
Figure 12-14 Start-up Timing
Table 12-35 Start-up Timing (V
DD
= 1.8 V to 3.6 V, T
A
= -20ºC to 75ºC)
Characteristic
Conditions
Symbol
Min
*
1
Max
*
1
Unit
Oscillator Start-up Time
t
START
5
sec
RESET
Hold Time
t
RESET
200
ns
RESET
High to
READY
Low
t
RHRL
76,800
76,800
T
*
2
Notes: 1. The specifications given in this data sheet indicate the minimum performance level of all
manufacturers of the FLEX decoder. Individual manufacturers may have better
performance than indicated.
2. T is one period of the ø
DEC
clock source. Note that from power-up, the oscillator start-up
time can impact the availability and period of clock strobes. This can affect the actual
RESET
high to
READY
low timing.