![Hitachi H8/3935 Hardware Manual Download Page 402](http://html.mh-extra.com/html/hitachi/h8-3935/h8-3935_hardware-manual_140486402.webp)
390
12.6.3
Reset Timing
The following diagram and table describe the timing specifications of the FLEX decoder when it
is reset.
t
RLRH
t
RL
RESET
READY
t
RHRL
Figure 12-15 Reset Timing
Table 12-36 Reset Timing (V
DD
= 1.8 V to 3.6 V, T
A
= -20ºC to 75ºC)
Characteristic
Conditions
Symbol
Min
*
1
Max
*
1
Unit
RESET
Pulse Width
t
RL
200
–
ns
RESET
Low to
READY
High
t
RLRH
–
200
ns
RESET
High to
READY
Low
t
RHRL
76,800
76,800
T
*
2
Notes: 1. The specifications given in this data sheet indicate the minimum performance level of all
manufacturers of the FLEX decoder. Individual manufacturers may have better
performance than indicated.
2. T is one period of the ø
DEC
clock source.