464
Table 19.6
Bus Timing
Condition:
T
a
= –20°C to +75°C (regular specifications), T
a
= –40°C to +85°C (wide-range
specifications)
Condition A: V
CC
= 2.7 to 5.5 V, AV
CC
= 2.7 to 5.5 V, V
REF
= 2.7 to AV
CC
, V
SS
= AV
SS
= 0 V
Condition B: V
CC
= 3.0 to 5.5 V, AV
CC
= 3.0 to 5.5 V, V
REF
= 3.0 to AV
CC
, V
SS
= AV
SS
= 0 V
Condition C: V
CC
= 5.0 V ± 10%, AV
CC
= 5.0 V ± 10%, V
REF
= 4.5 to AV
CC
, V
SS
= AV
SS
= 0 V
Condition
A
B
C
Test
Item
Symbol
Min
Max
Min
Max
Min
Max Unit
Conditions
Address delay time
Address hold time
Read strobe delay
time
t
AD
t
AH
t
RSD
—
0.5 t
cyc
– 45
—
50
—
60
—
0.5 t
cyc
– 35
—
40
—
50
—
0.5 t
cyc
– 20
—
25
—
25
ns
ns
ns
Figure 19.7,
figure 19.8
Address strobe
delay time
t
ASD
—
60
—
50
—
25
ns
Write strobe delay
time
t
WSD
—
60
—
50
—
25
ns
Strobe delay time
t
SD
—
60
—
50
—
25
ns
Write strobe pulse
width 1
t
WSW1
1.0 t
cyc
– 50
—
1.0 t
cyc
– 40
—
1.0 t
cyc
– 25
—
ns
Write strobe pulse
width 2
t
WSW2
1.5 t
cyc
– 50
—
1.5 t
cyc
– 40
—
1.5 t
cyc
– 25
—
ns
Address setup
time 1
t
AS1
0.5 t
cyc
– 45
—
0.5 t
cyc
– 29
—
0.5 t
cyc
– 20
—
ns
Address setup
time 2
t
AS2
1.0 t
cyc
– 45
—
1.0 t
cyc
– 35
—
1.0 t
cyc
– 20
—
ns
Read data setup
time
t
RDS
50
—
40
—
25
—
ns
Read data hold
time
t
RDH
0
—
0
—
0
—
ns