GENERAL DATA
2.1.7.
RPF & RPFI - FLOOR & FLOOR CONCEALED TYPE
MODELS RPF & RPFI
Units
RPF-1.0
RPF-1.5
RPF-2.0
RPF-2.5
RPFI-1.0
RPFI-1.5
RPFI-2.0
RPFI-2.5
Nominal Cooling Capacity
W
2800
4300
5600
7100
2800
4300
5600
7100
Nominal Heating Capacity
W
3300
4900
6500
8100
3300
4900
6500
8100
Air Flow Rate (Hi/Lo)
m
3
/min
8.5/7/6
12/10/9
16/14/11
16/14/11
8.5/7/6
12/10/9
16/14/11
16/14/11
Fan Motor
W
20
28
45
45
20
28
45
45
Sound Pressure Level
(Overalll A Scale)
(Hi/Me/Lo)
db (A)
35/32/29
38/35/31
39/36/32
42/38/34
35/32/29
38/35/31
39/36/32
42/38/34
Height
mm
630
630
630
630
620
620
620
620
Width
mm
1045
1170
1420
1420
863
988
1238
1238
Outer
dimensions
Depth
mm
220
220
220
220
220
220
220
220
Net Weight
kg
19
23
33
34
19
23
27
28
Color (Munsell Code)
-
Spring White (4.1Y 8.5 / 0.7)
---
Refrigerant
-
R407C (Nitrogen Charged in Factory for Corrosion-Resistance)
Connections
Refrigerant Piping
-
Flare-nut Connection (With Flare-Nuts)
Liquid Line
mm (in)
Ø6.35 (1/4)
Ø6.35 (1/4)
Ø6.35 (1/4)
Ø9.53 (3/8)
Ø6.35 (1/4)
Ø6.35 (1/4)
Ø6.35 (1/4)
Ø9.53 (3/8)
Gas Line
mm
(in)
Ø12.7
(1/2)
Ø12.7
(1/2)
Ø15.88
(5/8)
Ø15.88
(5/8)
Ø12.7
(1/2)
Ø12.7
(1/2)
Ø15.88
(5/8)
Ø15.88
(5/8)
Condensate Drain
mm
Ø18.5 OD
Ø18.5 OD
Ø18.5 OD
Ø18.5 OD
Ø18.5 OD
Ø18.5 OD
Ø18.5 OD
Ø18.5 OD
Packing Measurements
m
3
0.22
0.24
0.29
0.29
0.22
0.23
0.25
0.25
Optional Accessories
-
Remote Control Switch PC-P1HE or PC-2H2
OD: Outer Diameter
?
NOTE:
1. The nominal cooling and heating capacity is the
combined capacity of the HITACHI standard split
system, and are based on the JIS 158616.
Operation Conditions
Cooling
Heating
DB
27.0 °C
20.0 °C
Indoor Air Inlet Temperature
WB
19.0 °C
DB
35.0 °C
7.0 °C
Outdoor Air Inlet Temperature
WB
6.0 °C
Piping Length
: 7.5 meters;
Piping Lift
: 0 meter
DB
: Dry Bulb;
WB
: Wet Bulb
2. The Sound Pressure Level is based on the following
conditions:
– 1,5 meters beneath the Unit
– Voltage of the power source for the indoor fan motor
is 220V.
The above data was measured in an anechoic chamber
so that reflected sound should be taken into
consideration when installing the unit.
3. For more information about capacities, see chapter 4.
Summary of Contents for FSG Series
Page 2: ......
Page 4: ......
Page 13: ...3 57 7 1 7 ...
Page 14: ......
Page 110: ......
Page 116: ......
Page 146: ......
Page 160: ...9 14 CONTROL SYSTEM n Cooling Operation FSG FSG1 cont ...
Page 162: ...9 16 CONTROL SYSTEM n Cooling mainly Cooling Operation FXG FXG1 cont ...
Page 163: ...CONTROL SYSTEM 9 17 9 6 3 DRY OPERATION FSG FSG1 I U Indoor Unit O U Outdoor Unit ...
Page 164: ...9 18 CONTROL SYSTEM n Dry Operation FSG FSG1 cont ...
Page 165: ...CONTROL SYSTEM 9 19 9 6 4 DRY OPERATION FXG FXG1 I U Indoor Unit O U Outdoor Unit ...
Page 166: ...9 20 CONTROL SYSTEM n Dry Operation FXG FXG1 cont ...
Page 167: ...CONTROL SYSTEM 9 21 9 6 5 HEATING OPERATION FSG FSG1 I U Indoor Unit O U Outdoor Unit ...
Page 168: ...9 22 CONTROL SYSTEM n Heating Operation FSG FSG1 cont ...
Page 170: ...9 24 CONTROL SYSTEM n Heating mainly Heating Operation FXG FXG1 cont ...
Page 171: ...CONTROL SYSTEM 9 25 n Defrosting Operation Control ...
Page 173: ...CONTROL SYSTEM 9 27 9 7 2 GAS BYPASS CONTROL 9 7 3 OVER HEATING PROTECTION CONTROL ...
Page 176: ...9 30 CONTROL SYSTEM 9 7 6 CONTROL FOR AUTO COOL HEAT OPERATION ...
Page 228: ......
Page 229: ...3 57 167 7 21 7 ...
Page 230: ......
Page 324: ......
Page 344: ......
Page 376: ......
Page 423: ......