13
3. OPERATING PROCEDURE [Instrument Panel]
SELECT/WIDE
2
RUNNING CONTROL
START
REMOTE
1
FUNC
[×
10h
]
ALARM
STR
REMOTE
RUNNING MODE
AUTO START
POWER
LOAD
RESET
SHUTDOWN
STOP
Digital Monitor
Used for basic settings as well
as other various settings in
combination with the LCD monitor.
( 3.3.6)
●
ALARM light (green): Blinks if
an alarm failure occurs.
SELECT/WIDE
Button/Light (Yellow)
START
Button
Starts the air compressor.
The
START
light turns ON while
air compressor is running.
STOP
Button
Stops the compressor
immediately without unloading.
( 3.2.2)
UNLOAD STOP
Button
Stops the compressor in normal
state.
The compressor stops running
after removing the condensate
from the air end. ( 3.2.2)
REMOTE
Button
A c t i v a t e s o r d e a c t i v a t e s a
remote start/stop operation
locally or on the instrument
panel. ( 3.4.6).
UNLOAD STOP
Press this button to stop the air compressor.
The air compressor will stop after removing the
condensate from the air end.
※
This stop button is effective while a stand alone operation.
EMERGENCY STOP
button
Stops for emergency.
( 3.2.3)
●
POWER light (yellow): Lights up when the main power
is turned on.
●
REMOTE light (green):
ON (glowing) when the
REMOTE
button is pressed in
order to activate a remote operation.
ON (blinking) when an external remote-operation-
activation switch has been turned on in order to
activate a remote operation. ( 3.4.6)
●
LOAD light (yellow): ON (glowing) when the air
compressor is loading.
●
AUTO START light (green):
ON (glowing) while the air compressor is in a stop due
t o a n A U T O o p e r a t i o n , l e a d / l a g o p e r a t i o n , o r
scheduling operation.
ON (blinking) while the air compressor is in a stop due
to a restartable instantaneous power interruption.
( 3.3.3)
●
SHUTDOWN light (red): Blinks if a shutdown failure
occurs. ( 3.3.3)
RUNNING MODE
Light
S T O P
E
M
ERGENC
Y
Press to confirm the measurement
v a l u e s , s h u t d o w n h i s t o r y, a n d
setting status. ( 3.4.1, 3.4.2)
To s e t t h e E C O M O D E [ E n e rg y
saving mode] (Fixed speed type
only), hold down the
SELECT/WIDE
button for at least 7 seconds. The
light blinks and ECOMODE is set.