8. STANDARD COMPONENTS AND SUBSYSTEMS [Capacity Control System]
8.4.3 Typical Change of Pressure
⑴
Offline-or-Online, 0%-or-100%-Capacity, 2-Step
Control (Only for Fixed Speed Type)
Starting and
Pressure
Raising
Loading
Unloading
Loading
Air Receiver Pressure
Air End Outlet Pressure
Pr
essur
e
100
85
15
psi
Time
⑵
AUTO Operation
(
1
)
Stop Delay
(10 minutes)
(
2
)
Stop Delay
(30% load)
(
3
)
Start Delay
(15 seconds)
Starting
and
Pressure
Raising
Loading
Repeated
Loading/Unloading
Automatic
Motor Stop
Air Receiver Pressure
Air discharge pressure
after aftercooler
Pr
essur
e
Time
Automatic
Motor Restart
Indications on LCD
100
85
15
psi
Starting
and
Pressure
Raising
Loading
Unloading
Power Save Operation
load/unload cycling interval
(
standard 30 seconds
)
Loading Unloading
Air Receiver
Pressure
Air discharge pressure
after aftercooler
Pr
essur
e
Time
Loading
Unloading
Loading Unloading
100
85
15
psi
*
90
(
minimum
)
⑶
ECOMODE Operation
⑴
Stop Delay Time-Requires 15 seconds
of motor operation to sufficiently cool
down the motor.
If the third stop is done after 70
minutes or more has passed after
the first stop, the motor continues
to operate for 20 minutes after
restart of the air compressor, and
then return to the initial cycle.
⑵
Stop Delay Time – The air compressor
is continually calculating a load ratio.
If the load ratio is 30% and the motor
has stopped/restarted maximum 3
times for the past 90 minutes, then
the motor stops.
⑶
Stop Delay Time – Requires 10 seconds
t o c o m p l e t e l y e x h a u s t i n t e r n a l
compressed air and prepare to restart.
(Note)
ECOMODE setting
Target pressure: 90 psi (0.62 MPa)
Toad/unload cycling interval: 30 sec
The pressure with asterisk may vary
depending on the air receiver’s capacity
and the amount of air consumption.