Control line filter
Sight Glass
①
Stop the cooling water flow when the DSP has
stopped running.
②
Open the water drain peacock and the water drain
valve at the water drain port to remove the cooling
water from the system.
③
Take care to completely drain the cooling water
during the winter season to prevent freezing in the
cooling water pipes (
8.3
)
Water drain peacock
Water drain port
Cooling Water
5
●
Normally use the
UNLOAD STOP
button to stop
the air compressor. The air compressor then
unloads for 5 minutes and stops running.
(In the case of an emergency, press the
EMERGENCY
STOP
button to stop operation.)
Stopping operation
7
Control Line Filter
[Fixed speed type]
6
●
Check the sight glass on the control line filter to
make sure that the condensate discharged
properly.
11
2. GENERAL DESCRIPTION [Daily Operating Components]
Keeping the second-stage air end as dry as possible
is essential for preventing it from rusting due to a long
term operation suspension. When stopping the DSP,
therefore, execute an unloading operation and thereby
remove the moisture from the second-stage air end.