9. MAINTENANCE [How to Service the Air Compressor]
87
Air-Cooled
1
For light and non-greasy dust particle
①
Remove the right side cover, the front cover and the
rear cover.
②
Remove the right and left intake duct.
③
Remove the maintenance cover.
④
Use an air nozzle to blow the cooler surfaces.
2
For heavy and greasy dust particles
(detaching the cooler)
①
Remove the enclosure panels.
②
Drain the oil from the system.
③
Disconnect all the sensor wires from the cooler.
④
Disconnect all air / oil pipes at the joints.
⑤
Disconnect the discharge pipe.
⑥
Loosen and remove the cooler bolts.
3
For heavy and greasy dust particles
(cleaning the detached cooler):
①
Use an air nozzle to blow the cooler surfaces.
②
Soak the cooler in a detergent bath or spray
detergent onto the cooler. Use an air nozzle to blow
the cooler surfaces.
③
Generally, there are 3 kinds of dust and dirt particles.
・
Light dust particles
・
Heavy dust particles
・
Greasy dust particles
Contact the local HITACHI distributor/master
dealer or representative office for the detail.
Maintenance cover
Cooler duct plate (4)
Cooler duct
plate (5)
Maintenance cover
Right intake
duct
Left intake
duct
9
Cleaning of Cooler (Annually)