29
Installing the Z3210 Wireless Adapter
Installing/replacing the Z3210
You will need:
•
Phillips-head screwdriver (No. 2)
•
Model Z3210 Wireless Adapter
1
Remove the voltage sensors from the target under
measurement and turn off the instrument.
2
Loosen the screws that holds the battery cover in place with
the screwdriver and remove the cover.
3
Remove the protective cover from the Z3210 insertion slot.
4
Install the Z3210, observing the correct orientation, as far
as it will go.
5
Attach the protective cover into the Z3210 insertion slot.
6
Reattach the battery cover and tighten the screws.
Rear
Screws
Model Z3210
Protective cover
Battery cover
Z3210 insertion slot
M3 × 8 mm
To maintain the dust-proofness and water-proofness, put the protective
cover on the Z3210 insertion slot regardless of the presence or absence of
the Z3210.