4.6 Measuring Duty
Timer and Repetition Setting Examples
* Not available if RATE data is being retained (
TIME
displayed), but can be set if data is cleared.
To measure continuously
(Continuous measurement)
Press
SHIFT
→
(
START/STOP
) again to start mea-
suring.
START
is displayed.If the timer has been set, refer
to the following table regarding limitations.
To resume measuring after
clearing RATE data
(New measurement)
Press the
button and then the
button to clear
the measurement value, then press
SHIFT
→
(
START/STOP
).
To change the current thresh-
old
See "Current Threshold Setting" (page 80) to reset.
To cancel or change the timer
setting
Set again according to "Timer Setting" (page 82).
To view data by stopping the
display while measuring duty
(Data hold)
Press the
button. At this point, actual duty mea-
surement and elapsed time progress are not interrupted.
Display update is stopped, but duty measurement contin-
ues internally.
❖
See Section 5.5 "Data Hold" (page 96)
To determine the repetition
number of the occurring mea-
surement during repeating
measurement
Press the
button. The repetition number of the
occurring measurement is indicated on the bar graph.
To view history of RATE data
(Duty and Operating Time)
After pressing the
button (
HOLD
displayed), press
the
button.Press the
and
buttons to select on
the bar graph which data (that is, which repetition number)
to view. When multiple bars are displayed, the displayed
values are the duty and operating time up to the present.
❖
See Section 5.6 "Viewing Historical Data" (page 97)
To view history of PEAK data
(Peak values)
After pressing the
button (
HOLD
displayed), press
the
button.Press the
or
button to select on the
bar graph which measurement data (that is, which repeti-
tion number) to view. When multiple bars are displayed,
the displayed values are the peak, maximum and mini-
mum values from all measurements up to the present.
❖
See Section 5.6 "Viewing Historical Data" (page 97)
Timer Setting
Repetition Set-
ting
Start
Stop
Cumulative Integration
Timer Setting
1
None
None
Manual
Manual
Available
(Until stopped manually)
Not avail-
able
*
2
Yes (30 min)
None (Once)
Manual
Manual
(Before timer stops)
Available
(Stops 30 min after restart)
Timer (30 min)
3
Yes (30 min) Yes (Five times)
Manual
(Before timer stops)
Not available
Timer (5 x 30 min)