3.1 Measuring DC Current
39
1
2
3
4
5
6
7
8
9
10
B
asi
c M
easu
rem
e
nt
Proce
dure
3.1 Measuring DC Current
Sensor used
: Model 9691 CLAMP ON AC/DC SENSOR
Range
: AUTO
1.
Press the
button to select DC
(
).
Button presses are ignored if
TIME
is dis-
played: press
→
to clear it.
2.
Press
SHIFT
→
(
0 ADJ
) to execute
automatic zero adjustment.
is displayed.
3.
Clamp around a conductor to be mea-
sured so that it is centered in the
clamp.
The figure shows the 9691 CLAMP ON AC/
DC SENSOR.
The current direction mark on Models 9692
and 9693 CLAMP ON AC/DC SENSORs is in
a different location.
4.
Read the displayed value.
Since the range is AUTO, you do not need to
set it.
SOURCE
Electric
conductor
LOAD
The 9691 CLAMP ON AC/DC SENSOR
Position the clamp
with the current di-
rection indicator
pointing toward the
load side.