42
EURO 46 V10 Programming Manual
Fault
Description
Solution
I-01 (xx)
WLs LOW BATT
Low battery on wireless input number ‘xx’
Replace the battery on the input device mentioned.
B-01 (xx)
WLs LOW BATT
Low battery on wireless siren number ‘xx’
Replace the battery on the radio siren mentioned.
I-01 (xx)
WLs SUPERVN
Device on wireless input number ‘xx’ has not ‘checked
in’
Perform a walk test on the detector, and a diagnostic
signal strength test and then try replacing the battery.
B-01 (xx)
WLs SUPERVN
Wireless siren number ‘xx’ has not ‘checked in’ within
20 minutes time
Test the siren, perform wireless signal strength
diagnostic. Consider replacing the battery or
relocating the siren.
- 01 (xx)
CASE TAMPER
Tamper fault on input number 01
‘xx’ = any input number
Check the tamper switch on the detector and make
sure the case is closed properly.
WLs TAMPER
Bxx
Tamper fault on wireless siren number ‘xx’
Check the tamper switch on the radio siren
mentioned.
WLs JAMMING
Pnl
Jamming fault on the Enforcer Home Panel
Check no radio interference is in close proximity to the
radio devices/panel.
WLs Supervn
Fault
No ‘supervision polls’ were received for 20 minutes
before the setting operation. Wireless Input or Bell
input number will be shown so the problem is easily
identified
Test the signal strength/battery on each of the wireless
devices.
Input (xx)
Wirles Poll Fail
Wireless Poll Fail displays when no ‘polls’ (wireless
comms) are received for 20 minutes before the set
operation.
Test signal strength / battery status for each wireless
device (especially the one that corresponds to the
input named by the fault message).
IWLs Input / nput
Type Mismatch
Wireless devices are learned on inputs but no input
types have been programmed for them.
Program the input type for each of the wireless
devices learned in the CHANGE INPUTS.
Errors When Setting
Fault
Description
Solution
Please leave via
exit door
If the exit mode is programmed as Final Door, then the
premises must be left through this door for the system
to be set.
Leave via the agreed exit route.
Exit Via…
If any follow detectors or door contacts are open
during the setting procedure, a prompt will be
displayed to close them.
Close all inputs.
Unable To Set
A fault condition exists on the system. Details of the
fault will scroll on the display.
Correct the problem if it is an input which is open, or
call an engineer.
Alarm during the
setting
Fail to set time has been exceeded.
Leave the premises within the fail to set time, increase
the fail to set time in ‘timers’ or disable this feature in
system options.
Alarm during
the setting
procedure
Instant inputs have been activated.
During the setting procedure do not activate ‘instant
inputs’.
Access Levels
Level 1: Access by any person; such as the general public.
Level 2: User access by an operator; such as customers (If user code setup).
Level 3: User access by an engineer; such as an alarm company professional.
Level 4: User access by the manufacturer of the equipment.