49
EURO 46 V10 Programming Manual
NOTE: The user automation outputs can be also activated via the keypad or the key fob.
NOTE: The name of the output has to be one word and spelled exactly as written in the panel, such as: ‘Garage Door’ is not
acceptable. It has to be written as ‘Garage-Door’ in the panel and the respective command will be ‘Garage-Door’.
Checking the User Automation Outputs status via SMS text commands
Example SMS command send:
Description:
Example SMS command
response:
1234 Output 1 Status
123456 = User Code. User Output 1 status check.
OUTPUT ON or OUPUT OFF
123456 Output Garage-Door
Status
123456 = User Code. Output Garage-Door status check.
OUTPUT Garage-Door ON or
OUTPUT Garage-Door OFF
NOTE: The name of the output has to be one word and spelled exactly as written in the panel, such as: ‘Garage Door’ is not
acceptable. It has to be written as ‘Garage-Door’ in the panel and the respective command will be ‘Garage-Door’.
Editing an SMS telephone number via SMS text command
Example SMS command send:
Description:
Example SMS command
response:
123456 Change 07777888999
07878888999
123456 = User Code. Change number 07777888999 to
number 07878888999
NOTE: Use the country dialling code only for foreign SIM
cards.
CHANGE 07878888999
Start Uploading/Downloading via SMS text command
Example SMS command send:
Description:
Example SMS command
response:
123456 UDL
123456 = User Code. UDL = The Enforcer will make an
outgoing data connection to the programmed PC1 number.
No response as the panel is
already connected to the PC1
9999 UDL
9999= Engineer Code UDL = The Enforcer will make an
outgoing data connection to the programmed PC1 number.
No response as the panel is
already connected to the PC1
Summary of Contents for Pyronix EURO 46 V10