20
EURO 46 V10 Programming Manual
10. ‘Set Point Sets’ will be displayed. Select the area(s).
Press
.
11. ‘Set Point Unsets’ will be displayed. Select the area(s).
Press
.
12. ‘Set Point In’ will be displayed. Enter the Area in which
the Arming Station is situated and press
.
13. ‘Set Point Description’ will be displayed. Press
to
enter the name and location if required.
14. ‘Enter Name’ will be displayed. Enter the name of the
wireless Arming Station and press
.
15. ‘Enter Location’ will be displayed. Enter the location of
the wireless Arming Station and press
.
16. Press
b
or
d
to select another device address
to program 7 - 9 or press the
key to return to the
Engineer menu.
Change Timers?
Timers
Description
Options
Entry Time
(01ABCD)
Programs the entry time for each area.
PLEASE NOTE:
Ensure that the timer is no longer than 45 seconds in order to comply with
EN50131-1.
0-255 seconds
Entry Time 2
Same as above therefore allowing for different timers on 2 entry routes.
0-255 seconds
Exit Time
(01ABCD)
Programs the exit time for each area.
0-255 seconds
APP Exit
Time
Programs the exit time for each area that is applied when the area is set using the
Home Android or iOS App.
PLEASE NOTE:
This time must be set at 30 seconds or more to comply with
PD6662:2010+IA:2015.
0-199 seconds
Siren Time
(01ABCD)
Program the length of time an external sounder will be audible for.
2-15 minutes
Siren Delay
The delay after the intruder alarm before bell activates.
PLEASE NOTE:
Not valid within three minutes of final set, or after entry time started. If ‘Silent
1st Alarm’ is selected in alarm responses the delay commences at confirmed alarm.
0-20 minutes
Confirm
Time
Time period during which a second activation must occur to qualify as a ‘sequentially
confirmed’ alarm.
PLEASE NOTE:
BS8243 specifies a confirm time between 30 and 60 minutes. This can also
be used in conjunction with testing an omit signal.
1–99 minutes
HU Confirm
Time
Time period during which a second activation on a hold alarm must occur to qualify as a
‘sequentially confirmed’ alarm.
PLEASE NOTE:
BS8243 specifies a confirm time between eight and 20 hours. This can also
be used in conjunction with testing an omit signal.
8 – 20 hours
Set Points Sets
[01ABCD]
Set Point Unsets
[01ABCD]
Set Point In
[01ABCD]
Set Point
Description?
Enter Name
Station 01
Enter Location
_