16
EURO 46 V10 Programming Manual
Type
The device types that are available will depend upon the selected address:
LCD keypads [0], Readers [1] Not Used [2], Arming Stat [3]
Reader is
If a reader is installed, the following options can be assigned to the reader:
[0] Set Point:
Reader used for setting and unsetting.
[1] Ward Control:
A reader can be used to create wards. For example: A keypad may control a full
area, but within that area you may wish to control certain inputs only.
[2] Access Control:
If an access control system is installed then the reader must be programmed as
this type. The lock open time and door open time can be programmed (in seconds).
[3] Unset Only:
Select this type if the reader is to be used as an unset device only.
[4] Entry Control:
This option is used when the reader is used to lock/unlock doors and also is to be
used to set and unset the system. This option is used in conjunction with ‘tag opens doors’ which can
be found in ‘Site Options’ which is a sub-menu within ‘SYSTEM OPTIONS?’ The lock open time and
door open time can be programmed (in seconds).
Programming Keypads: Assign Keypads/Readers
1. Press
b
or
to scroll to ‘ASSIGN KEYPADS/
READERS’. Press
.
2. Press
b
or
d
to select the address. Press
.
3. ‘Type’ will be displayed. Press
to select
‘Keypad’.
Press
4. ‘Set Point Sets’ will be displayed. Select the area(s).
Press
.
5. ‘Set Point Unsets’ will be displayed. Select the area(s).
Press
.
6. ‘Set Point In’ will be displayed. Enter the Area in which
the keypad is situated and press
.
7. ‘Set Point Description’ will be displayed. Press
to
enter the name and location if required.
8. ‘Enter Name’ will be displayed. Enter the name of the
keypad and press
.
ASSIGN KEYPADS/
READERS?
Address
[1]
Type
Keypad [0]
Set Point Sets
[01ABCD]
Set Point Unsets
[01ABCD]
Set Point In
[01ABCD]
Set Point
Description?
Enter Name
Device 01