EURO 46 V10 Programming Manual
Display Inputs
If 'Yes’, then the keypad display will show any inputs that are activated in unset mode.
PLEASE NOTE:
This must be programmed as ‘No’ to ensure compliance with EN 50131.
Exit Modes
Exit Mode
Description
[0] Timed
Providing that all inputs are closed, the system will only set when the programmed 'Exit Time' has
expired.
[1] Final Door
The system will only set when an input programmed as 'Final Exit 1' or 'Final Exit 2' opens and
closes.
[2] Timed/Final
This function follows the 'timed' operation, except that the timer will be overridden if an ‘Final Exit’
input is opened and closed before the timer expires.
[3] Push To Set
The system will only set when a 'Push to Set' button has been pressed. This function will override the
programmed 'Exit Time'. The button can be used as a door bell when the ‘Chime’ input attribute is
enabled.
PLEASE NOTE
: If the setting has not been completed within the programmed exit time, it is possible
to generate an alarm or return to unset mode. These parameters are defined in ‘Change Timers’ and
the sub-menu ‘Site Options’ located in ‘System Options’.
Review Logs?
There are two logs available on the system; panel and access control. Each log displays the most
recent event first. Use
b
and
d
to move forwards and backwards through the log. To view
additional details, press the
c
key. If no other information is available, the display will move to the
next log entry. Press
a
or
c
again, to return to the main screen for that log entry.
PLEASE NOTE:
In any unset or set period, the control panel will only log a maximum of three
occurrences of any particular event.
PLEASE NOTE:
It is not permitted under EN50131-1 to delete any logs. The only circumstance in
which the logs can be cleared, is part of the ‘Clean Start’ operation.
The Panel Log?
Includes Set, Unset, Trouble, User, Alarm, Engineer Access, Time & Date changes etc.
The Access/Control Log?
Includes all Access Control and Guard Tour events.
Engineer Tests?
The Engineer Tests function allows the engineer to test inputs, outputs, batteries and the bell.
Sound To Play
This function allows you to listen to the different tones the system/keypad(s) makes. They have a
choice of: Chime Single, Chime Follow, Exit Fault, Entry, Tech Fault, Tamper, Alarm, HU (Hold Up),
and Fire.
Walk Test
PLEASE NOTE:
If any programming changes have been made, please exit then re-enter the
Engineer Menu before commencing any walk tests.
This function allows the engineer to test all the programmed inputs on the system. The inputs that
have not been activated will be shown on the display. Once all the inputs have been walk tested,
‘Walk Test Completed’ will be displayed. When walk-testing a double-knock detector, it must be
triggered twice within the pre-set period. When testing dual-trip detectors you must first open
detector one and then trigger the second detector; next open the second detector and trigger the