5.6.7 Wiegand Wiring
Note
Connect the OK/ERR/BZ if the access controller should control the LED and buzzer of the Wiegand
card reader.
5.6.8 Barrier Control Wiring
By default, the barrier has connected with the access control board. The lane control board can
control the barrier status. If possible, the device can connect with a third party lane control board
to control the third party barriers. Interface D1 controls barrier opening for entrance, while
interface D2 controls barrier opening for exit.
Note
Use the jumper cap to switch the relay status. For details, see Barrier Control Relay Output Mode .