114
alarm, exception and all.
For operation major type, there are many minor types, including Power On, Shut
Down, Abnormal Shut, Panel Login, Panel Logout, Panel Config, Panel File Play, Panel
Time Play, Local Start Record, Local Stop Record, Panel PTZ, Panel Preview, Panel Set
Time, Local Upgrade, Net Login, Net Logout, Net Start Record, Net Stop Record, Net Start
Transparent Channel, Net Stop Transparent Channel, Net Get Parameter, Net Config, Net
get Status, Net Alert On, Net Alert Off, Net Reboot, BiComStart (Start Voice Talk),
BiComStop (Stop Voice Talk), Net Upgrade, Net File Play, Net Time Play, Net PTZ.
For alarm major type, the minor type includes: External Alarm In, External Alarm Out,
Motion Detect Start, Motion Detect Stop, View Tamper Start, View Tamper Stop.
For exception major type, the minor type includes: Video Signal Loss, Illegal Access,
Hard Disk Error, Hard Disk Full, IP Conflict, DCD Lost.
For example: The steps of viewing alarm log.
Step 1:
For “Query” item, select “By Type” to active “Major Type” and “Minor Type”
items.
Step 2:
For “Major Type” option, select “Alarm” option. For “Minor Type” option, select
one of following options: All, External Alarm In, External Alarm Out, Motion Detect Start,
Motion Detect Stop, View Tamper Start, View Tamper Stop.
Step 3:
Move “Active Frame” to “Search Log” button, press
[
ENTER
]
key to start
searching.
Step 4:
When searching is finished, DVR will list all matched alarm information. In the
list box, the information includes: Index, Occur Time, Major Type, Minor Type, Panel User,
Net User, Host Address, Para. Type, Channel No, HDD No, Alarm In and Alarm Out. You
can press “More Info” button for more information, also select page number to view more
information.
Step 5:
Press “Return” button back to “Utilities” menu.
By Time
View the log between one time period.
Step 1:
Select “By Time” for “Query” option to active “Start Time” and “Stop Time”
items.
Summary of Contents for DS-7000HI Series
Page 11: ...11 1 4 Typical Application ...
Page 14: ...14 5 Connect HDD and main board with HDD cable Then connect HDD s power cable ...
Page 27: ...27 How to exit menu Press PREV or ESC key to exit menu and return to preview mode ...
Page 54: ...54 In this case press ENTER to return password edit box and input new password again ...
Page 60: ...60 ...
Page 70: ...70 ...
Page 108: ...108 Step 6 You can preview the image of 192 1 0 2 by using client end software ...
Page 125: ...125 In the formula a means alarm occurrence rate ...
Page 127: ...127 The corresponding relationship of cross cable ...
Page 137: ...137 Suggestions ...