15
Note
You should enable the Panel Management Notification function in Communication
Parameters → Event Communication before enabling the Late to Disarm function.
Weekend Exception
Enable the function and the zone will not be armed in the weekend.
Holiday Exception
Enable the function and the zone will not be armed/disarmed in the holiday. You should set
the holiday schedule after enabling.
Note
Up to 6 holiday groups can be set.
Auto Arm Sound Prompt
After disabled, the buzzer will not beep before auto arming.
Panel Alarm Duration
The time duration of the panel alarm.
Note
The available time duration range is from 10 s to 900 s.
5. Click Save.
Fault Check
The fault check here is only for the control panel in the normal status.
The system determines whether to check the faults listed on the page. The system will only check
the fault that is selected.
Click System → System Options → System Fault Check to enter the page.