Double knock
After enabled, the time interval can be set. If the same detector is triggered twice or
continuously in a period of time, the alarm will be triggered.
Sounder Delay Time
The sounder will be triggered immediately (0s) or after the set time.
Final Door Exit
Only magnetic contacts have this option.
After enabling, when the user use keypads or tags to arm:
-Arm With Faults is enabled: During the arming countdown, if the magnetic contact is
triggered and then restored, the arming process will be terminated immediately after
restoring, and the arming is completed.
- Arm With Faults is disabled: If the magnetic contact is triggered and then restored, the
linked area immediately arms the delayed zone.
Dual Zone
After enabled, when multi transmitter detects that the entire zone circuit of the local zone
and the extended zone is open circuit, both zones trigger lid opened alarms.
Timer With Restart
During the Exit Delay process, the exit delay time will be re-timed at the time when the
second delay zone was triggered.
3.3.6 User Management
The installers (user of Hik-Connect) can manage users. If you are the administrator, you can add,
edit, and delete users, and assign different permissions to the newly-added users.
Steps
Note
There are four types of users for the AX HYBRID PRO, including administrator (or owner),
operator, and installer (or setter). Different types of users have different permissions for
accessing the functionality of the AX HYBRID PRO.
1. Enter the site, tap the AX HYBRID PRO and then log in to the device (if required) to enter the AX
HYBRID PRO page.
2. Tap Next to invite the user.
Note
The recipient need to accept the invitation.
3. Tap
→ User Management → User.
4. Tap a user to enter the User Management page.