background image

 

122 

 

SIA code 

CID code 

Description 

YR 

3311 

Battery Reconnected 

TA  (The  serial  number  of 
output module starts from 1, 
of keypad starts from 101, of 
tag reader starts from 201) 

1144  (The  serial  number  of 
output module starts from 1, 
of keypad starts from 101, of 
tag reader starts from 201) 

Lid Opened 

TR  (The  serial  number  of 
output module starts from 1, 
of keypad starts from 101, of 
tag reader starts from 201) 

3144  (The  serial  number  of 
output module starts from 1, 
of keypad starts from 101, of 
tag reader starts from 201) 

Lid Restored 

YP 
Transmitter AC power Loss 
ID range: 301~ 
Sounder AC power Loss 
ID range: 202~ 

1301 
Transmitter AC power Loss 
ID range: 301~ 
Sounder AC power Loss 
ID range: 202~ 

Expander AC Power Loss 

YQ 
Transmitter AC power Loss 
ID range: 301~ 
Sounder AC power Loss 
ID range: 202~ 

3301 
Transmitter AC power Loss 
ID range: 301~ 
Sounder AC power Loss 
ID range: 202~ 

Expander AC Power Loss Restored 

TA 

1144 

Lid Opened 

TR 

3144 

Lid Restored 

TA 

1144 

Lid Opened 

TR 

3144 

Lid Restored 

XL 

1381 

Device Offline 

XC 

3381 

Device Restored 

TA  (The  serial  number  of 
output module starts from 1, 
of keypad starts from 101, of 
tag reader starts from 201, of 
transmitter starts from 301) 

1144  (The  serial  number  of 
output module starts from 1, 
of keypad starts from 101, of 
tag reader starts from 201, of 
transmitter starts from 301) 

Lid Opened 

TR  (The  serial  number  of 
output module starts from 1, 
of keypad starts from 101, of 
tag reader starts from 201, of 
transmitter starts from 301) 

3144  (The  serial  number  of 
output module starts from 1, 
of keypad starts from 101, of 
tag reader starts from 201, of 
transmitter starts from 301) 

Lid Restored 

XT  (The  serial  number  of 
output module starts from 1, 
of keypad starts from 101, of 
tag reader starts from 201, of 
transmitter starts from 301) 

1384  (The  serial  number  of 
output module starts from 1, 
of keypad starts from 101, of 
tag reader starts from 201, of 
transmitter starts from 301) 

Battery Low 

XR  (The  serial  number  of 
output module starts from 1, 
of keypad starts from 101, of 
tag reader starts from 201, of 
transmitter starts from 301) 

3384  (The  serial  number  of 
output module starts from 1, 
of keypad starts from 101, of 
tag reader starts from 201, of 
transmitter starts from 301) 

Battery Voltage Restored 

Summary of Contents for AX HYBRID PRO

Page 1: ...AX HYBRID PRO User Manual...

Page 2: ...YOU IS AT YOUR OWN RISK IN NO EVENT WILL HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL CONSEQUENTIAL INCIDENTAL OR INDIRECT DAMAGES INCLUDING AMONG OTHERS DAMAGES FOR LOSS OF BUSINESS PROFITS BUSINESS IN...

Page 3: ...y by design principles For example for device with facial recognition features biometrics data is stored in your device with encryption method for fingerprint device only fingerprint template will be...

Page 4: ...n death or serious injury Caution Indicates a potentially hazardous situation which if not avoided could result in equipment damage data loss performance degradation or unexpected results Note Provide...

Page 5: ...S Directive 2011 65 EU 2012 19 EU WEEE directive Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union For proper recycling return this product to yo...

Page 6: ...ings 35 3 1 5 Communication Settings 35 3 1 7 Maintenance 50 3 1 8 Check Status 55 3 2 Set up with Hik Proconnect 55 3 3 Set up with Hik Connect 77 3 4 Report to ARC Alarm Receiver Center 100 Setup AT...

Page 7: ...Arming Process is Not Started 109 A 5 Operational Failure 109 A 5 1 Failed to Enter the Test Mode 109 A 5 2 The Alarm Clearing Operation on the Panel Does Not Produce the Alarm Clearing Report 109 A 6...

Page 8: ...M Besides this hybrid control panel supports customized voice library which is designed for users to upload customized voice files These voice files will be played via alarm phone call when alarm trig...

Page 9: ...Note Standard DC 09 Protocol ADM CID The data presenting method of DC 09 is CID which is not encrypted and only for uploading alarm report ADC CID The data presenting method of DC 09 is CID which is e...

Page 10: ...password of your own choosing using a minimum of 8 characters including upper case letters lower case letters numbers and special characters in order to increase the security of your product And we r...

Page 11: ...r usually regarded as administrator Step2 Configure the Network on APP 1 Download Hik Connect Hik ProConnect and log in 2 Power on the AX HYBRID PRO 3 Turn the Wi Fi mode switch to HOTSPOT 4 Connect y...

Page 12: ...7 Tap Wireless Connection and tap Next 8 The APP will automatically fill in the home Wi Fi currently used by the mobile phone into the page as shown in the figure below After confirming the Wi Fi pass...

Page 13: ...ication code and tap OK The verification code is on the device label 11 The APP will search the device Wi Fi automatically Check whether the connected Wi Fi is belonged to the target device and tap Co...

Page 14: ...7 to the mobile phone should with name HAP_serial number AX HYBRID PRO serial number 12 Follow the prompts turn the Wi Fi mode switch to WLAN 12 Wait for connection...

Page 15: ...ome Wi Fi signal is good the control panel will successfully log in to cloud and complete the binding before the countdown ends 2 When the home Wi Fi signal is unstable the control panel may not be co...

Page 16: ...a new countdown You can wait for the connection If you want to change the home Wi Fi you should change the home Wi Fi connected to the mobile phone first then press the RESET button of the control pa...

Page 17: ...Search the device IP address via the client software and the SADP software 3 Enter the searched IP address in the address bar 4 Enter the user name and password to login Note Only the admin and the i...

Page 18: ...time automatically with NTP Check the check box of NTP Time Sync enter the server address and port No and set the synchronization interval You can synchronize the device time manually Or check Sync wi...

Page 19: ...ptions page Or the Forced Auto Arm Forced Arming function cannot be valid Forced Arming After enabled when manual arming starts if there are active faults in a zone the zone will be automatically bypa...

Page 20: ...estore Motion detectors include all PIR detectors Disable No automatic restore Immediate After Alarm Motion detectors automatically restores immediately after the alarm and reports to Cloud for APP an...

Page 21: ...eps rapidly 1 minute before the auto arming starts You can select to enable forced arming on the System Options page While the function is enabled the system will be armed regardless of the fault Enab...

Page 22: ...holiday schedule after enabling Note Up to 6 holiday groups can be set Auto Arm Sound Prompt After disabled the buzzer will not beep before auto arming Panel Alarm Duration The time duration of the p...

Page 23: ...led when the cellular data network is disconnected or with other faults the alarm will be triggered Panel Main Power Lost If the option is enabled an alarm will be triggered when the control panel mai...

Page 24: ...ess Early Alarm A delay zone is triggered first and the area is in the Entry Delay stage During the delay time period an instant zone is triggered At this time the area enters the early alarm stage Th...

Page 25: ...rly Alarm Delay Zone Instant Zone Alarm Disarm Silence No Alarm OR Device Enroll Mode Click Enter the Enrollment Mode to make the panel enter the enroll mode Security Settings SSH Settings Enable or d...

Page 26: ...the user locked duration Note To compliant the EN requirement the system will only record the same log 3 times continuously Steps 1 Click System System Security User Lockout Attempts to enter the Lock...

Page 27: ...for the programmed time duration once the module authentication has failed for the amount of configured times Steps 1 Click System System Security Module Locking Settings to enter the Module Lock Set...

Page 28: ...k Enroll to add a zone 3 Select Relate Mode Wireless Enter Serial Number and select Detector Type Select Main Device Type and Main Device Name Click OK it will start enrolling Power on the detector an...

Page 29: ...ults first and then the zone is in arming process If the delay zone is triggered within the exit delay time but it restores before the time ends the alarm will not be triggered and the zone will be ar...

Page 30: ...d or not Report fire alarm after triggering Gas Zone 24 hour active zone whether armed or not Report gas alarm after triggering Follow Zone The zone acts as delayed zone when it detects triggering eve...

Page 31: ...the zone will disarm When the zone is in alarm the disarmed areas linked with the zone cannot be armed Stay Arm Bypass The zone will be automatically bypassed in stay arming Cross Zone PD6662 is not e...

Page 32: ...and the arming is completed Arm With Faults is disabled If the magnetic contact is triggered and then restored the linked area immediately arms the delayed zone Dual Zone After enabled when multi tran...

Page 33: ...nked to area 1 by default 5 Check the link event 6 Enable Sounder Tamper Alarm 7 Click OK Note After the sounder is configured you can click Maintenance Device Status Sounder Status to view the sounde...

Page 34: ...horization Only standard mode has this function You can select the authorization method Active on Entry Delay When someone enters the delay zone the screen and backlight of the keypad will be on This...

Page 35: ...ters of the keyfob Steps 1 Click Device Keyfob to enter the page 2 Click Enroll to add a keyfob 3 Click to edit the keyfob parameters 4 Enable the keyfob 5 Select a linked user 6 Configure the functio...

Page 36: ...pe the tag the system will upload a record 6 Click OK Automation You can set the parameters of the relay outputs that is enrolled Steps 1 Click Device Automation to enter the page 2 Click Enroll enter...

Page 37: ...f alarm arm disarm and fault event Activation Mode Latched Continue the output until the relay is manually closed or opened Pulsed The relay will be closed open after the set duration Contact Status N...

Page 38: ...e camera SADP Scanning Scan all network cameras in the same LAN A list will pop up after scanning You can directly check to add cameras in the list 4 Click OK 5 Optional Click Edit or Delete to edit o...

Page 39: ...ase enter a number in the range 0 to 63 The address range should be continuous 4 Click Scan Updating to see if there are devices can be added Note The scan takes 1 minute If the peripheral and the con...

Page 40: ...ll and enter the basic information of the camera such as IP address and port No and select the protocol type 3 Enter the user name and password of the camera SADP Scanning Scan all network cameras in...

Page 41: ...ew it has a high resolution code rate and picture quality Sub Stream It is used to transmit network and preview pictures as a video streaming with features of lower resolution bit rate and picture qua...

Page 42: ...ct an area 3 Check Enable 4 Check the check box to select zones for the area 5 Click Save 3 1 5 Communication Settings Wired Network You can set the device IP address and other network parameters Step...

Page 43: ...ain name 4 Click Save Wi Fi You can set the Wi Fi parameters if there are secure and credible Wi Fi networks nearby Steps 1 Click Communication Wi Fi to enter the Wi Fi page 2 Connect to a Wi Fi Manua...

Page 44: ...ave Cellular Network Set the cellular network parameters if you insert a SIM card inside the device By using the cellular network the device can upload alarm notifications to the alarm center Before Y...

Page 45: ...s Password Ask the network carrier and input the password APN Ask the network carrier to get the APN information and enter the APN information Data Usage Limit You can enable the function and set the...

Page 46: ...alarm center Steps 1 Click Communication Alarm Receiving Center to enter the Alarm Receiving Center page 2 Slide the slider to enable the selected alarm receiver center 3 Select the connection type as...

Page 47: ...nge from 10 to 3888000 seconds ISUP CSV IP You do not need to set the protocol parameters SIA DCS or ADM CID You should select the Address Type as IP or Domain name and enter the IP address port numbe...

Page 48: ...gured with FSK or RDC and the center cannot be used as a standby channel 5 Click Save Use PIRCAM to Upload Pictures or Videos You can enable the PIRCAM function to upload pictures or videos 1 Upload P...

Page 49: ...y Email Enable Video Verification Events and set corresponding parameters For details see Notification by Email Click Save Configure FTP parameters Click Communication FTP to enter the FTP Settings pa...

Page 50: ...ide the slider to enable the selected alarm receiver center 3 Select the Protocol Type as SIA DCS 4 Click Save 5 Configure SMTP or FTP parameters as same as Upload Photos Notification Push When an ala...

Page 51: ...rm of any peripheral is triggered or restored Panel Lid Opened The device will push notifications when lid opened alarm of the control panel is triggered or restored Panic Alarm The device will push n...

Page 52: ...notifications when any peripheral status is changed Panel Operation The device will push notifications when the user operate the control panel Smart Alarm Event The device will push notifications whe...

Page 53: ...red your customized content will be added at the beginning of the message sent by the system 5 Click Save Note For mobile phone notification You need to press to finish the call It is required to add...

Page 54: ...ity The connection priority order from high to low is wired network Wi Fi cellular data network Wired Wi Fi The system will select wired network first If no wired network detected it will select Wi Fi...

Page 55: ...will be attached with alarm video 4 Enter the receiver s information 5 Click Receiver Address Test and make sure the address is correct 6 Click Save NAT Universal Plug and Play UPnP is a networking ar...

Page 56: ...FTP Type Set the FTP type as preferred or alternated FTP Protocol FTP and SFTP are selectable The files uploading is encrypted by using SFTP protocol Server and Port The FTP server address and corres...

Page 57: ...te Note Both of the users and configuration information will be retained after upgrade finished View Licenses You can view device name and other information Click Maintenance Device Information About...

Page 58: ...art time and end time and click Filter All filtered log information will be displayed in the list You can also click Reset to reset all search conditions Test The AX HYBRID PRO supports walk test func...

Page 59: ...ngs 4 Trigger the detector in each zone 5 Check the test result System Maintenance You can reboot the device restore default settings import export configuration file Select the device and click in th...

Page 60: ...eters to the device Importing configuration file requires entering the password set at the time of exporting Export Configuration File Click Export Configuration File to export the device configuratio...

Page 61: ...Server to the system The device will upload web logs to the server Steps 1 Click System Maintenance Device Maintenance Security Audit Log to enter the page 2 Check Enable Log Upload Server 3 Enter log...

Page 62: ...BRID PRO such as activation device enrollment etc 3 2 1 Download and Login the Hik ProConnect Download the Hik ProConnect mobile client and login the client before operating the AX HYBRID PRO Steps 1...

Page 63: ...the device serial No and verification code to add the device 4 Activate the Device 3 2 3 Add Peripheral to the AX HYBRID PRO Add peripheral to the AX HYBRID PRO Steps 1 Select a control device AX HYBR...

Page 64: ...page tap the AX HYBRID PRO and then log in to the device if required to enter the page Enable Alarm Tap to select Audible Panic Alarm or Silent Panic Alarm View Faults Tap to view faults Area Manageme...

Page 65: ...elect areas following operations will take effect for all areas Away Arming Tap to away arm selected areas When all the people in the detection area leave turn on the Away mode to arm all zones in all...

Page 66: ...ime but it restores before the time ends the alarm will not be triggered and the zone will be armed Arm with faults is disabled Immediately armed If the delay zone is triggered within the exit delay t...

Page 67: ...the disarmed status if the zone is triggered the linked area will be armed Trigger the zone again and the area will be disarmed By Zone Status You need to choose to arm or disarm the linked area afte...

Page 68: ...he zone is restored If the second zone is triggered within the set time both zones will give alarms Otherwise no alarm will be triggered If the first zone is not be restored both zones will give alarm...

Page 69: ...t the entire zone circuit of the local zone and the extended zone is open circuit both zones trigger lid opened alarms Timer With Restart During the Exit Delay process the exit delay time will be re t...

Page 70: ...set the keypad password to the target user Change Duress Password If the target user is an administrator or an operator you can tap the target user on the user list and then tap Change Duress Password...

Page 71: ...ag page 5 Optional Tap a Tag to enter the Setting Page 6 Tap Edit Icon to edit the Tag name Note If you log in as an installer skip this step Editing tag name is only available to administrator The na...

Page 72: ...bypass You can use keyfobs tags and keypads to arm zones or manually arm zones on APP Single multiple or all areas can be selected for arming Note You should disable the Arm With Faults in the Arm Op...

Page 73: ...After Alarm Motion detectors automatically restores immediately after the alarm and reports to Cloud for APP and ARC After Disarm Motion detectors automatically restores after disarming and reports t...

Page 74: ...he alarm will be triggered Panel Mains Power Lost If the option is enabled an alarm will be triggered when the control panel main supply is disconnected Panel Mains Power Loss Delay The system checks...

Page 75: ...one Entry Delay Trigger Instant Zone Early Alarm Delay Zone Instant Zone Alarm Disarm Silence No Alarm Trigger Delay Zone Entry Delay Trigger Instant Zone Early Alarm Delay Zone Instant Zone Alarm Dis...

Page 76: ...deo streaming with features of lower resolution bit rate and picture quality Bitrate Type Select the Bitrate type as constant or variable Resolution Select the resolution of the video output Bitrate T...

Page 77: ...tion Parameters Event Communication before enabling the Late to Disarm function Late to Disarm Time Set the time point mentioned in Late to Disarm Weekend Exception If enabled Auto Arm Auto Disarm and...

Page 78: ...and set parameters including the user name access password APN MTU and PIN code 5 Tap Save Icon 6 Enable Data Usage Limit 7 Edit Data Used This Month and Data Limited per Month Access Number Input th...

Page 79: ...is triggered or restored Panel Lid Opened The device will push notifications when lid opened of the control panel is triggered or restored Panic Alarm The device will push notifications when panic ala...

Page 80: ...will be added at the beginning of the content of the phone dialed by the system You can also tap Clear to delete audios Note Only WAV format is supported up to 512 KB and 15 s 7 Check notifications A...

Page 81: ...pany as None Hungary Multi Alarm Receiving Company or French Alarm Receiving Company Intruder Verification as a Service The SDK returns the URL address of the video storage after the PIRCAM composite...

Page 82: ...vice if required 2 Tap Communication Parameters Notification by Emails to enter the page 3 Enable Email 1 4 Enter the sender name sender email address SMTP server address SMTP port user name and passw...

Page 83: ...other hardware devices The UPnP protocol allows devices to connect seamlessly and to simplify the implementation of networks in the home and corporate environments Enable the UPnP function and you don...

Page 84: ...if required 2 Tap Maintenance Remote Log Collection to enable the function Remote Log Collection is for getting logs relating to the device When this is enabled our technical support will be able to c...

Page 85: ...Results page 5 Enter the verification code and tap OK 6 After adding completed enter the device alias and tap Save 7 Optional Tap Delete Device to delete the device 8 Optional Tap to edit the device n...

Page 86: ...isarm areas view device status etc On the device list page tap the AX HYBRID PRO and then log in to the device if required to enter the page Enable Alarm Tap to select Audible Panic Alarm or Silent Pa...

Page 87: ...elect areas following operations will take effect for all areas Away Arming Tap to away arm selected areas When all the people in the detection area leave turn on the Away mode to arm all zones in all...

Page 88: ...ime but it restores before the time ends the alarm will not be triggered and the zone will be armed Arm with faults is disabled Immediately armed If the delay zone is triggered within the exit delay t...

Page 89: ...the disarmed status if the zone is triggered the linked area will be armed Trigger the zone again and the area will be disarmed By Zone Status You need to choose to arm or disarm the linked area afte...

Page 90: ...he zone is restored If the second zone is triggered within the set time both zones will give alarms Otherwise no alarm will be triggered If the first zone is not be restored both zones will give alarm...

Page 91: ...hat the entire zone circuit of the local zone and the extended zone is open circuit both zones trigger lid opened alarms Timer With Restart During the Exit Delay process the exit delay time will be re...

Page 92: ...f the target user is an administrator or an operator you can tap the target user on the user list and then tap Change Duress Password to set the duress password to the target user Note If under duress...

Page 93: ...enter the Card Tag page 3 Tap to add a tag 4 When hearing the voice prompt Swipe Tag you should present the tag on the AX HYBRID PRO tag presenting area When hearing a beep sound the tag is recognized...

Page 94: ...he auto arming disarming schedule and linked areas Note You should disable the Arm With Faults in the Arm Options page Or the Forced Auto Arm Forced Arming function cannot be valid Forced Arming After...

Page 95: ...rs and peripherals whose heartbeat loss times exceed the set value will be shown as offline Bypass on Re Arm While enabled after the detector is bypassed if its faults are restored and the linked area...

Page 96: ...s the device will upload events LAN Lost If the option is enabled when the wired network is disconnected or with other faults the alarm will be triggered WiFi Lost If the option is enabled when the Wi...

Page 97: ...enters the early alarm stage There are control panel voice alarm and local sounder alarm but no alarm message is pushed If the zone is disarmed or silence before both the early alarm and entry delay...

Page 98: ...etwork Camera Event Video Settings to enter the page 3 Select a camera and set the video parameters Stream Type Main Stream Being used in recording and HD preview it has a high resolution code rate an...

Page 99: ...Auto Arming Sound Prompt After disabled the buzzer will not beep before auto arming Late to Disarm Enable the device to push a notification to the phone or tablet to remind the user to disarm the area...

Page 100: ...equired 2 Tap Communication Parameters Wi Fi Configuration to enter the page 3 Tap a Wi Fi to connect in the list Cellular Data Network Steps 1 In the site tap the AX HYBRID PRO and then log in to the...

Page 101: ...n to the device if required 2 Tap Communication Parameters Push Notification s to enter the page 3 Enable the target notification Zone Alarm Lid Opened The device will push notifications when the zone...

Page 102: ...l Set Numbers of Calling For SMS Set Arming Permission Disarming Permission and Alarm Clearing Permission for areas Common Message You can enter message content When the alarm is triggered your custom...

Page 103: ...the number of retry attempts Polling Option Set the polling rate with the range from 10 to 3888000 seconds The system will report fault if the time is over the limit The status of device will be show...

Page 104: ...red network first If no wired network detected it will select Wi Fi network Cellular Data Network The system will select cellular data network only 4 Enable Periodic Test Enter the periodic test inter...

Page 105: ...ission to upload pictures If the FTP server supports picture uploading by anonymous users you can enable Anonymous to hide your device information during uploading Directory Structure The saving path...

Page 106: ...Fi Connection You can make the AX HYBRID PRO connect to Wi Fi through APP Steps 1 On the device list page tap the AX HYBRID PRO and then log in to the device if required to enter the page 2 Tap Config...

Page 107: ...EN 50131 10 and EN 50136 2 Category DP2 is provided with primary network interface of LAN Wi Fi and secondary network interface of GPRS or 3G 4G LTE ATS Alarm Transmission system is designed to always...

Page 108: ...anagement and assign an account for the panel as show below Setup ATS in Transceiver of the Panel Steps 1 Login using installer account from local web client 2 Click Communication Alarm Receiving Cent...

Page 109: ...IP Domain Name Server Address Domain Name Port No Input IP address or domain name by which the transceiver of receiving center could be reached Input port number of the server provided by the ARC Acc...

Page 110: ...ts Setup the maximum number that re transmission will be tried Polling Rate Setup the interval between 2 live polling if enable is checked Encryption Setting Encryption Arithmetic AES Password Length...

Page 111: ...an be also assigned with installer user at particular access level to perform essential operations Access Entries for the Administrator and Operators Access Level 2 Hik Connect Service The Hik Connect...

Page 112: ...Panic alarm device triggered Lid opened tamper alarm occurred Communication exception Main power supply exception Backup battery exception Alarm receiving fault Sounder fault Low battery of the keyfo...

Page 113: ...oute when the AX HYBRID PRO is in the status of entry delay the AX HYBRID PRO then enters the early alarm mode The early alarm duration can be set 30s The AX HYBRID PRO will reports the alarm only if...

Page 114: ...abnormal 2 The panel port has been modified Please add a port to the web address for further access A 1 3 Hik Connect is Offline Fault Description The web page shows that the Hik Connect is offline So...

Page 115: ...nrollment Mode Fault Description Click the panel function key and prompt key invalid Solution The panel is in Hotspot mode Switch the panel to station mode and then try to enter the enrollment mode ag...

Page 116: ...atus A 5 Operational Failure A 5 1 Failed to Enter the Test Mode Fault Description Failed to enable test mode prompting A fault in the zone Solution Zone status alarm status or zone power is abnormal...

Page 117: ...cation not safe enough The device can send mails normally 2 Gmail does not remove CAPTCHA authentication Solution Click the link below and then click continue https accounts google com b 0 displayunlo...

Page 118: ...ahoo smtp mail yahoo com 587 STARTTLS TLSv1 2 126 smtp 126 com 465 SSL TLS Sina smtp sina com 25 465 587 SSL TLS STARTTLS SSL TLS Note About mail configuration SMTP portDefault to use port 25 without...

Page 119: ...alarm Delayed Zone The system provides you time to leave through or enter the zone without alarm Audible Response Trigger the system sound and sounder Voice Prompt Zone X alarm Follow Zone The zone a...

Page 120: ...abled Zone Alarms will not be activated when the zone is triggered or tampered Audible Response No system sound voice prompt or sounder Virtual Zone Keypad Keyfob The system will immediately alarm whe...

Page 121: ...114 Input Types Operations Fault event displays on client You can handle the fault via client software or mobile client Voice Prompt Armed Arming failed...

Page 122: ...delay Alarm When alarm event occurs The alarm output will be activated after the configured exit enter delay After the configured output delay disarm the AX HYBRID PRO or silence alarm Zone Linkage Wh...

Page 123: ...e D 1 Event Types Event Types Custom Default 1 client software notification Default 2 alarm receiving center 1 2 Default 3 mobile client Default 4 telephone Alarm and Tamper Life Safety Event System S...

Page 124: ...n Code No Yesd Yesd Adding Editing Level 2 User and Verification Code No Yes Yes Adding Editing Configuration Data No No Yes Replacing software and firmware No No No Note a By the condition of being a...

Page 125: ...ypassed the user level 3 can login the controller without the permission assignment of the user level 2 The user level 4 can login the controller only when the user level 2 or level 3 has assigned per...

Page 126: ...They will also be recorded to mandatory log memory with capacity of 1000 records allocated in non volatile flash memory storage as well as the ATS fault record The detail of reports and log records ar...

Page 127: ...A 1122 Silent Panic Alarm HH 3122 Silent Panic Alarm Restored 1133 24H Alarm 3133 24H Alarm Restored NA 1780 Timeout Alarm BH 3780 Timeout Alarm Restored PA 1120 Panic Alarm Audible Panic Alarm PH 312...

Page 128: ...ns Power Restored YT 1302 Battery Low YR 3302 Battery Voltage Restored ZY 1305 Reset to defaults YM Transmitter battery missing ID range 301 1311 Transmitter battery missing ID range 301 Battery Disco...

Page 129: ...1 Device Restored TA The serial number of output module starts from 1 of keypad starts from 101 of tag reader starts from 201 of transmitter starts from 301 1144 The serial number of output module sta...

Page 130: ...LT 1351 Main Signalling Path Fault LR 3351 Main Signalling Path Restored LT 1352 Backup Signalling Path Fault LR 3352 Backup Signalling Path Restored AM 1354 Telephone Line Disconnected CU 3354 Teleph...

Page 131: ...estored AZ 1776 Sudden Decrease of Sound Intensity Alarm DF 3776 Sudden Decrease of Sound Intensity Alarm Restored Audio Input Fault Audio Input Restored BA 1131 Line Crossing Alarm BH 3131 Line Cross...

Page 132: ...Unregistered Tag XL 1381 Device Offline XC 3381 Device Restored XT 1384 Battery Low XR 3384 Battery Voltage Restored XL The serial number of output module starts from 1 of keypad starts from 101 of ta...

Page 133: ...on Alarm Stopped BJ 1941 Device Blocked DM 3941 Device Blocking Alarm Restored Video Signal Loss Video Signal Restored Input Output Format Unmatched Input Output Format Restored Video Input Exception...

Page 134: ...306 Device Enrolled CE 1306 Device Deleted EB 3306 Device Enrolled CF 1306 Device Deleted 3306 Device Enrolled CG 1306 The serial number of output module starts from 1 of keypad starts from 101 of tag...

Page 135: ...pport The device has admin installer operator account You can use these accounts to access and configure the device User Privacy Information Description Password The password for the device account us...