89
3.3.10 Fault Check
The fault check here is only for the control panel in the normal status.
The system determines whether to check the faults listed on the page. The system will only check
the fault that is selected.
Steps
1. On the device list page, tap the AX HYBRID PRO and then log in to the device (if required) to
enter the page.
2. Tap
→ System → System Options → System Fault Check to enter the page.
Detect Network Camera Disconnection
If the option is enabled, when the linked network camera is disconnected, an alarm will be
triggered. The delay time of network camera disconnection detection is the same as that of
LAN.
Panel Battery Fault Check
If the option is enabled, when panel battery is disconnected or in low battery status, the device
will upload events.
LAN Lost
If the option is enabled, when the wired network is disconnected or with other faults, the alarm
will be triggered.
WiFi Lost
If the option is enabled, when the Wi-Fi is disconnected or with other faults, the alarm will be
triggered.
Cellular Lost
If the option is enabled, when the cellular data network is disconnected or with other faults, the
alarm will be triggered.
Panel Mains Power Lost
If the option is enabled, an alarm will be triggered when the control panel main supply is
disconnected.
Panel Mains Power Loss Delay
The system checks the fault after the configured time duration after AC power down.
To compliant the EN 50131-3, the check time duration should be 10 s.
3.3.11 Arm Options
This function is for the whole alarm system, to inform the user of the current system status before
arming. If it is enabled, there will be a fault prompt and confirmation process for keypads, keyfobs,
Summary of Contents for AX HYBRID PRO