ID3000 Series Smart Code Reader User Manual
67
range frames and specific frame. If specific frame is selected as Local Save Picture Strategy, you
need to set Local Picture Index.
Profinet Output Format
It selects what contents you want to output, including code content, code type, angle, trigger
start time, code score, etc. You can select multiple contents according to actual demands.
Profinet Format Check
You should click Execute in Profinet Format Check to check if you entered is right in format, and
the check result will be displayed in Profinet Format Check Result.
Profinet Output NoRead
If it is enabled, and the device will output the content you set in Profinet Output NoRead Text
when no code is recognized.
Profinet Output Start Text
The contents of the start part of the data outputted. You can set the contents according to actual
condition.
Profinet Output Stop Text
The contents of the end part of the data outputted. You can set the contents according to actual
condition.
Profinet Output Barcode Enter Character Enable
If it is enabled, enter character will be outputted.
Profinet Output Barcode Newline Character Enable
If it is enabled, a newline will be outputted.
Profinet Output Barcode Carriage Return Enable
If it is enabled, a carriage return will be outputted.
Profinet Add NoRead Enable
You can add contents to let the device output codes when the code recognized by the device does
not meet the min. length requirement. It includes Off, Add Noread, and Just Noread. Off does
not add contents and the device outputs code recognized only. Add Noread allows you to add
contents to the min. length requirement and output. Just Noread means that the device outputs
Noread only if the code recognized by the device does not meet the min. length requirement.
Code Pos Width Enable
If it is enabled, you can add 0 to codes if the code coordinate does not meet specified length.
Code Pos Width
You can enter the length of the code coordinate after enabling Code Pos Width Enable.
CodeNum End Trigger Min
If it is enabled, the device will stop triggering and save the current image when the code
recognized by the device does not meet the min. length requirement.