ID3000 Series Smart Code Reader User Manual
52
Select Acquisition Start Active
If acquisition starts, the output signal will be triggered. When you select Acquisition Start Active
as Line Out Activation Event, you can set its output delay time and duration.
Line Out Delay Time
It sets the delay time for outputting the output signal.
Line Out Duration
It sets the time duration of the output signal.
Figure 8-37 Select Acquisition Start Active
Select Acquisition Stop Active
If acquisition stops, the output signal will be triggered. When you select Acquisition Stop Active as
Line Out Activation Event, you can set its output delay time and duration.
Line Out Delay Time
It sets the delay time for outputting the output signal.
Line Out Duration
It sets the time duration of the output signal.