ID3000 Series Smart Code Reader User Manual
29
Note
●
The lens focus function may differ by device models.
●
Setting the device mode as Test is required before setting lens focus. After completion, you can
set the device mode as Normal.
●
Setting the trigger mode as off is required before setting lens focus.
Auto Focus
Steps
1. Click
in the live view window.
2. Go to Image Settings → Auto Focus, and click Execute in Focus Mode.
The device starts to adjust focus automatically.
3. Select the position parameter from Focus Position, and click Execute in Focus Position Save to
save the focus position.
4. (Optional) Select the position parameter from Focus Position, and click Execute in Focus
Position Load to load saved focus position.
Figure 8-6 Auto Focus
Manual Focus
1. Go to Image Settings → Auto Focus, and set Focus Step according to actual demands.
2. Click
or
in Adjust Focus to adjust focus.
3. Select the position parameter from Focus Position, and click Execute in Focus Position Save to
save the focus position.
4. (Optional) Select the position parameter from Focus Position, and click Execute in Focus
Position Load to load saved focus position.