ID3000 Series Smart Code Reader User Manual
25
Figure 8-2 Single Mode
Multiple Mode
Note
●
The parameter of Best Polling Group Idx is used to display the polling parameter number when
the device recognizes codes after enabling polling. If the polling is disabled or polling parameters
are edited, it displays 1 by default.
●
The rule for multiple-mode polling is that the polling is started from the polling parameter with
Best Polling Group Idx, and then execute other polling parameters you selected in turn. For
example, if the Param3 is the Best Polling Group Idx and Param1, Param2, Param4 and Param5
are enabled, the polling order is Param3 > Param1 > Param2 > Param4 > Param5.
Steps
1. Go to Image Settings → Image → Polling Enable, and select Multiple as Polling Enable.
2. Set Polling Time and Polling Period according to actual demands.
3. Select 2 to 8 sets of parameters (e.g. Param1 and Param2) from Polling Param, and enable
Polling Param Enable to let them take effect.
4. Set Polling Exposure Time, Polling Gain, and Polling Gamma for the Polling Param you selected.
5. Select Polling Light Selector according to actual demands, and enable Polling Light Enable.
6. Repeat step 3 to step 5 to set other parameters from Polling Param.