ID3000 Series Smart Code Reader User Manual
43
images.
Steps
1. Click I/O Control Settings → Input → Trigger Mode.
2. Select On as Trigger Mode.
3. Select Software as Trigger Source.
4. Click Execute in Trigger Source to send trigger commands.
You can also enter Auto Trigger Time, and then enable Enable Auto Trigger to let the client
software automatically send trigger signal to device according to the interval you set.
Figure 8-20 Set and Execute Software Trigger Mode
Set and Execute Hardware Trigger Mode
Steps
1. Click I/O Control Settings → Input → Trigger Mode.
2. Select On as Trigger Mode.
3. Select the specific line as Trigger Source according to actual demands.
4. Set Debounce Time and Line Out Trigger In Polarity according to actual demands.
Note
●
When selecting Rising Edge or Falling Edge as Line Out Trigger In Polarity, you can set Trigger
Delay.
●
When selecting Level High or Level Low as Line Out Trigger In Polarity, you can set Start Delay
Time and End Delay Time according to actual demands.