PREDATOR XS TURNTABLE STRETCH WRAPPER OPERATION MANUAL
HIGHLIGHT INDUSTRIES, INC. ● 2694 PRAIRIE SW; WYOMING; MI 49519 ● 1-800-531-2465
II-13
Cutler-Hammer AC Drive Parameter Settings
Page Groups
Parameters are grouped in a page arrangement.
Each page will contain a list of the parameters
associate with that group. Move into the page
groups from the display menu by using the right
arrow key.
Parameter Groups
Select the desired parameter group by using the
up and down keys. Once the parameter group is
located, use the right arrow key to enter the group.
Use the up and down keys to scroll the parameters
on that page.
Parameters
Once the parameter has been located, use the
right arrow key to view the parameter setting.
Programming Mode
Use the ENTER key to enter the programming
mode. The displayed parameter will flash
indicating the parameter can be changed.
Parameter Changes
Use the up and down keys to change the
parameter setting. Press ENTER to enter the new
parameter setting.
If the parameter change is successful, the keypad
will display the end (End) message and return to
the parameter number display. If the parameter
change is unsuccessful the keypad will display an
error (Err) message, the parameter will not be
changed, and the parameter number will again be
displayed.
To Exit Programming Mode
Pressing left arrow backs out of Parameter Mode
and returns you to Display Mode.