PREDATOR XS TURNTABLE STRETCH WRAPPER OPERATION MANUAL
HIGHLIGHT INDUSTRIES, INC. ● 2694 PRAIRIE SW; WYOMING; MI 49519 ● 1-800-531-2465
II-20
Optional Scale Package
Optional Scale Package
Optional Scale Package
Optional Scale Package
The optional scale package allows the user to quickly measure the weight of a package placed on
the machine. To operate correctly and efficiently the scale needs to be configured with the correct
settings. Below are instructions on how to configure the scale and the settings that are pre-
programmed by Highlight Industries, Inc.
Setting Configuration
Step 1: Turn the scale display over and turn off the scale power.
Step 2: Remove the two small screws holding a small plate on the back of the scale.
Step 3: Flip the switch under the plate to the right.
Step 4: Turn the scale power back on.
Step 5: Press the “PRINT / >>” button until the desired setting appears on the screen.
Step 6: Press the “ZERO” button to enter the parameter set-up.
Step 7: Press the “PRINT / >>” button until the display reads the correct setting and press the
“SET / NET” button.
Step 8: Turn the power back off, flip the switch under the plate to the left, and turn the power back
on.
Step 9: Replace the screws on the back cover and retighten the scale swivel grips on the side.
Step 10: The scale is now ready to use.
Current Settings:
F1 = 5000
F2 = 100
F3 = 3
F4 = 100
F5 = 1
F6 = 8
F7 = 2%
F8 = 1
F9 = 1
F10 = 0