PREDATOR XS TURNTABLE STRETCH WRAPPER OPERATION MANUAL
HIGHLIGHT INDUSTRIES, INC. ● 2694 PRAIRIE SW; WYOMING; MI 49519 ● 1-800-531-2465
V-9
NO
YES
Locate the film
delivery frequency
drive inside the
electrical
enclosure. Is the
LED display on?
Is the frequency
drive functioning
(i.e. no faults
reported)?
Refer to frequency
drive manufacturer’s
manual for specific
fault.
Push the “STOP”
button. Wait sixty
seconds, and then pull
the button out. Does
this clear the fault?
Adjust the switch so
that it activates
when the dancer
bar is pulled.
Locate the film
carriage dancer bar
limit switch. Is it
positioned correctly?
Tighten wiring to the
sensor, replace if
necessary.
.
Refer to Power
Problem above.
With machine
power
properly
supplied, pull
the dancer
bar on the
carriage.
Does the film
mandrel
rotate?
Problem fixed. Film
delivery is ready.
Continued to page V-10
Is the film delivery
circuit breaker on?
Switch the circuit
breaker on.
Locate the dancer bar
limit switch input to the
PLC. Does the
indicator light turn on
as the dancer bar is
pulled?
Locate the film delivery
motor, and use a
voltmeter to check
continuity of all motor
wires. Is the frequency
drive connected
properly to the motor?
Restore drive
parameters setting.
Tighten or replace
wiring as necessary.
Look up the frequency
drive parameters
setting listed on the
electrical schematics.
Are all parameters set
correctly?
Film Delivery Problem