Technobeam
®
User Manual
Powering On the Fixture
2-3
Status LEDs
Technobeam fixtures have three status LEDs located on the access
door, as shown in Figure 2-2:
Figure 2-2. Location of the three status LEDs on the fixture’s access door.
Table 2-1 describes the three status LEDs:
If the LED states indicate a problem, see the section titled
“Troubleshooting” on page 2-20.
* - The Receive LED will not be ON unless the fixture is connected to a
DMX 512 link with a working controller. If you have already connected
Table 2-1. Status LEDs
LED name
State
Problem
Indication?
Description
Motor
solid red
No
The motors are receiving adequate
voltage.
OFF
Yes
Fuse or power failure. See below.
Transmit
OFF
Not necessarily* No data is being transmitted.
flickering yellow
No
A software crossload is taking place.
solid yellow
Yes
†
Software or hardware failure.
Receive
OFF
Not necessarily* No data is being received.
flickering green
No
Fixture is receiving data.
Door retaining screw
Access door