Technobeam
®
User Manual
Optional Accessories
1-5
Environmental Specifications
Maximum ambient temperature (T
a
):
50° C (122° F)
Maximum exterior surface temperature:
70° C (158° F)
Minimum distance to flammable objects:
1.0 m (3.28 ft)
Minimum distance to lighted object:
1.0 m (3.28 ft)
DMX Data Cabling
•
DMX data cables:
Belden
®
9841 or equivalent (meets
specifications for EIA RS-485 applications) with characteristics
listed below:
•
2-conductor, twisted pair plus a shield
•
maximum capacitance between conductors - 30 pF/ft.
•
maximum capacitance between conductor & shield - 55 pF/ft.
•
maximum resistance of 20
Ω
/1000 ft.
•
nominal impedance 100–140
Ω
•
22–24 AWG with insulation having a dielectric rating of 300
volts or higher
•
DMX data connectors:
3-pin male and female XLR connectors
•
DMX data terminators:
Male XLR connector with 120 ohm
terminator between pins 2 and 3 (see Figure 2-4 on page 2-6)
Controllers
Technobeam may be controlled with any of the following:
•
The Status Cue
®
lighting system
•
The Technobeam LCD controller
•
Another DMX 512-compatible controller
Optional Accessories
Table 1-1 below shows the optional accessories for Technobeam,
available from your High End Systems
®
dealer/distributor:
Table 1-1. Optional Accessories
Name
Part Number
Optional lens sets
Call*
Replacement MSD 250-2 lamp
Call*
Custom color wheel dichroic filters
Call*
LithoPatterns
Call*
Summary of Contents for Technobeam
Page 2: ...ADDR...
Page 3: ......
Page 15: ...xii Technobeam User Manual...
Page 20: ...iii Ecodome User Manual 2...
Page 21: ...Ecodome User Manual iv...
Page 23: ...Ecodome User Manual ii...
Page 145: ...6 26 Technobeam Laser Aiming Device Technobeam User Manual...