OLP Release
(3)
Red light on: OLP crane
Red light blinking: OLP Release crane
Green light on: dump 2 active (if present)
OLP Release
(4)
Green light on: Dump 1 active.
OLP Release
(3)
(4)
Green light on both
③
④
: Stabiliser functions are
activated (dump 1 and 2 active).
Stabiliser leg/
extension
(5)
Not active.
Automatic duty
control
(6)
Green light on: Increased capacity (ADC mode).
Hoist LED
(7)
Not active.
Cylinder
pressure LED's
(8)
Green light A on: 50% of OLP pressure.
Green light A - B on: 70% of OLP pressure.
Red light A - C flashes: 90% of OLP pressure.
Red light A - D on: 100% of OLP pressure.
Red light blinking from A to D: OLP Release.
Manual extension
(9)
Not active.
Slewing sector
(10)
Green light on: Outside slewing sector, normal
capacity.
Light off: Inside slewing sector, reduced capacity.
Red light on: OLP. Vehicle has reached a stability
limit. (Also all the 1st boom diodes will light red).
Lamp test for the User Interface SPACE 3000
See: Daily inspection.
The Safety system
40