96
Appendix B Explanation of Protocol command
Another device can operate Total station through RS232 or
Bluetooth by using the commands as follow:
"\006006",0-- command correct response
"\021021",1-- command incorrect response
"C067\003",2-- measure and return the data
"N078\003",3-- stop measuring
"ZA0043\003",4—direct to close
"ZA1067\003",5-- direct to open
"Z10091\003",6--H/V
"Z12089\003",7--HR
"Z13088\003",8--HL
"Z20088\003",9--H/V
"Z31088\003",10—SD track
"Z32091\003",11--SD loose measurement
"Z33090\003",12—SD repeat loose measurement
"Z34093\003",13—SD accurate measurement
"Z35092\003",14—SD repeat accurate measurement
"Z41095\003",15--HD tracking measurement
"Z42092\003",16--HD loose measurement
"Z43093\003",17--HD repeat loose measurement
"Z44090\003",18—HD accurate measurement
"Z45091\003",19—HD repeat accurate measurement
"Z51094\003",20—VD tracking measurement
"Z52093\003",21—VD loose measurement
"Z53092\003",22—VD repeat loose measurement
"Z54091\003",23—VD accurate measurement
"Z55090\003",24—VD repeat accurate measurement
"Z61093\003",25—NE tracking measurement
"Z62094\003",26—NE loose measurement
"Z63095\003",27—NE repeat loose measurement
"Z64088\003",28—NE accurate measurement
"Z65089\003",29—NE repeat accurate measurement
"Z71092\003",30—NE tracking measurement
"Z72095\003",31—NE loose measurement
"Z73094\003",32—NE repeat loose measurement
"Z74089\003",33—NE accurate measurement
"Z75088\003",34—NE repeat accurate measurement
"Z81083\003",35—Z tracking measurement
"Z82080\003",36—Z loose measurement
"Z83081\003",37—Z repeat loose measurement
"Z84086\003",38—Z accurate measurement
"Z85087\003",39—Z repeat accurate measurement