55
dHR: a negative value indicates a clockwise rotation of the
alidade. Inversely, positive value indicates a anticlockwise
rotation.
dHD: a positive value indicates that the lens should shift to
the instrument. Inversely, a negative value indicates that it should
shift away.
dN: a negative value indicates that the lens can reach to
expected stakeout point if moving north. Inversely, it should
move south.
dE: a negative value indicates that the lens can reach to
expected stakeout point if moving east. Inversely, it should move
west
dZ: a negative value indicates that the lens can reach to
expected stakeout point if moving downwards (excavation).
Inversely, it should move upwards (fill).
Nex.P: press it to stake out the next point. You may find the
coordinate of the next point in the selected file and go back to the
page of „Stake out: XX‟ . Press „ENT‟ to stake out the next point
directly.
9.2.2 Fast station
When the current control station and the staking out point
are not intervisible , you may have to set a new point as a control
station.The fast station function is now helpful to you.
Press „Meas‟ to measure the coordinate of the new control
station. Save it into proper file . „Sequence‟, „same point‟ and
„edit point‟ functions under „Config of survey‟ is valid here as
well.
VZ: 90°12′22″
HR: 200°54′12″
N: -10.756m
E: 8.607
Z: -0.004
T.H
Mode
Meas