38
If the measurement is saved successfully, it displays box of
„Record:****** ‟ for 0.5 second and switch back to the
Coordinate Mode.
Meas:
Press soft key „F2‟ to start EDM. The instrument will
calculate out the coordinate of the target point and display the
result. If the current distance measurement mode is continue or
tracking mode, you may press „ESC‟ to quit distance
measurement, otherwise press ‟ANG‟ or „DIST‟ to stop distance
measurement and switch to Angle or Distance Mode.
Mode: The same as the key „Mode‟ under Distance Mode
On the Second Page:
Settings:
Press soft key „F1‟ to enter the Settings of „Height of Ins. &
Target‟
After finishing entering, press „ENT‟ or the soft key „Save‟
to save the settings. However the settings will be erased when
shutting off if using „ENT‟ to save; inversely, using soft key
„Save‟ will remain the setting forever providing that there is no
change of the setting. Press „ESC‟ to quit without saving. If you
want to check view the instrument height and target height ,you
can go to the page above.
The range for I.H and T.H is between -99.999m to 99.999m.
If over the range, a box of „I.H overtop!‟ or „T.H overtop!‟ will
appear on the screen.
If you want the settings of height is effective for the next
boot ,press soft key „Save‟ to record the instrument height and
target height into system file.
BSS:
Press soft key „F2‟ to enter page of „BBS‟ as followed:
Height of Ins.&Target
I.H
:
T.H
:
m
B.S
Clear
Save
Enter