![Henny Penny KVE-071 Operator'S Manual Download Page 36](http://html1.mh-extra.com/html/henny-penny/kve-071/kve-071_operators-manual_2124340036.webp)
July 2014
29
This mode gathers and stores historic information on the fryer and op-
erator’s performance. Press and hold
for 3 seconds, until *INFO*
*MODE*” shows on the displays.
Press ▲ or ▼ buttons to access the steps and press
√
button to view the
statistics within each step.
This mode includes the following information:
1.
FILTER STATS
- filtering information for the last 7 days
2.
REVIEW USAGE
- information accumulated since the last time
this data was manually reset
3.
LAST LOAD
- information about the most recent Cook Cycle, or
the cycle presently in progress
NOTE: Press X button to exit from the Information Mode.
1.
FILTER STATS
Press
√
button to select Filter Stats and then press ◄ and ► to select the
day you want to view the stats. Then press ▲ or ▼ buttons to view the fol
-
lowing stats:
•
“FILTERED” = Number of times filtered
•
“FLT BPSD” = Number of times filtering was skipped
•
“FLT AVG” = Average number of cook cycles between filters
2.
REVIEW USAGE
Press
√
button to select Review Usage and press ▲ or ▼ buttons to view
the following:
FUNCTION
DISPLAY EX.
Day the usage data was previously reset
SINCE 8:26A 4-19-10
Total number of cook cycles
TOTAL COOKS 462
Cook Cycles stopped before “PULL”
QUIT COOK
4
Number of hours the fryer was on (left)
Number of hours the fryer was on (right)
L ON HRS
165
R ON HRS
160
Reset Usage Data
RESET - YES NO
3-19
INFORMATION
MODE
Summary of Contents for KVE-071
Page 2: ......
Page 4: ......
Page 14: ...July 2014 8a Casters adjustable up to 1 562 in 40mm 2 9a DIMENSIONS...
Page 27: ...July 2014 20 NO Make sure vat is full and then press button...
Page 55: ......