PURGE VALVE HANDLE
Cook Position (open)
9.
Display shows “CLOSE RETURN VALVE” followed by
“CONFIRM”. Allow oil to bubble for 10 to 15 seconds and
then close the yellow return valve handle. Press
√
button
and the control returns to normal operation.
NOTE
: Purge valves are available on select units for solid
shortening. Perform step 10 if purge valve is available, otherwise
continue to step 3-12.
10.
Display shows “OPEN BLACK PURGE VALVE”
followed by “CONFIRM”.
NOTE
: This prompt only displays if the unit is
enabled for Solid Shortening in the settings. Liquid
shortening is the preferred oil.
IMPORTANT:
Leave purge valve in closed position if more vats
need filtered. Press
√
button and leave purge handle in the filter
(closed) position repeat above steps.
Once all vats have been filtered, open purge valve, press
√
button.
To help ensure the vat fills completely, make sure filter pan is cleaned at least
daily, filter pad is changed, and that “O” rings on the filter pan are in good
condition.
3-11.
QUICK FILTER
(CONT.)